Bogen BOGEN WV100, WV250 Manual Important Safety Information, Domestic and International Listings

Page 2

Notice

Every effort was made to ensure that the information in this guide was complete and accurate at the time of printing. However, information is subject to change.

Important Safety Information

WARNING: To Reduce The Risk of Fire Or Electric Shock, Do Not Expose This Apparatus To Rain Or Moisture.

Always follow these basic safety precautions when installing and using the unit:

1. Read these instructions.

2.Keep these instructions.

3.Heed all warnings.

4.Follow all instructions.

5.Do not use this apparatus near water.

6.Clean only with dry cloth.

7.DO NOT block any ventilation openings. Install in accor- dance with the manufacturer’s instructions.

8.Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9.Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade, or the third prong, are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11. Only use attachments/accessories specified by the manufac- turer.

12. Unplug this apparatus during lightning storms or when unused for long periods of time.

13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

Domestic and International Listings

UL and CSA Listed

IMPORTANT

CAUTION: TO PREVENT THE RISK OF ELEC- TRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.

The lightning flash with arrowhead sym- bol, within an equilateral triangle, is intended to alert the user to the pres- ence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equi- lateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompa- nying the appliance.

Image 2
Contents Installation and Use Manual Important Safety Information Domestic and International ListingsContents Wall-Mount Power Vector Front Panel Panel DescriptionsWall-Mount Power Vector Module Bay Rear Wall-Mount Power Vector Connector Board RearFront Panel Input Connector InstallationPackage Contents MountingOutput Modules Module InstallationModules Input ModulesTransformer-Coupled Speaker Connections ConnectionsSpeakers Ohm Low-Impedance Speaker ConnectionsBridging Mix Bus Remote Volume ControlMute Control COM and GND TerminalsSystem Expansion of Power Vector Amplifiers Front Panel Controls & Indicators OperationOutput Limiter Trans Output / Direct Out Selector SwitchRear Panel Controls Block Diagram Specifications Troubleshooting Warranty Accessories/Components

WV250 Manual, BOGEN WV100, WV150 specifications

The Bogen WV150, WV100, and WV250 are part of Bogen's versatile line of public address systems designed for various applications. Each model packs unique features while sharing common technologies that enhance performance and usability, making them ideal for businesses, schools, and other institutions that require effective audio solutions.

The Bogen WV150 is a powerful yet compact unit that delivers excellent sound quality. It features a 150-watt amplifier that ensures clear audio distribution, making it suitable for mid-sized venues. The unit comes with an integrated mixer, allowing users to connect multiple microphones and playback devices seamlessly. The WV150 also supports various input types, including XLR for professional microphones and RCA for media players, enhancing its versatility.

Bogen's WV100 is designed for smaller settings or personal use. This model boasts a 100-watt amplifier for clear sound at lower volumes. It’s ideal for classrooms and small group presentations. The WV100 is lightweight and portable, featuring a built-in carrying handle. Despite its smaller size, it still incorporates an intuitive mixer and multiple input options, making it an excellent choice for educators and small businesses.

The WV250 offers higher power output at 250 watts, making it suitable for larger venues such as auditoriums or outdoor events. This model includes advanced digital signal processing features, improving sound quality and reducing distortion. The WV250 also includes a built-in compressor circuitry for dynamic range management, ensuring that loud sounds don’t overpower quieter ones, thus maintaining a consistent audio experience.

All three models rely on Bogen’s commitment to reliability and sound fidelity. They feature durable housings designed to withstand the rigors of daily use while remaining aesthetically pleasing. Each model includes user-friendly controls, making it easy for anyone to operate without extensive training.

In summary, the Bogen WV150, WV100, and WV250 are robust public address solutions packed with features designed for a range of applications. From the portability of the WV100 to the robust power of the WV250, these models are engineered to provide clear, reliable audio for any setting. The combination of performance, flexibility, and build quality positions Bogen's WV series as a leading choice in public address technology, catering to diverse audio needs across varied environments.