Appendix E Skew Module

The Cobra R1300A / R1300S2 receivers have an optional skew compensation module that can be installed or removed.

To install the skew compensation module:

1.Remove top cover.

2.Remove the 3 jumpers from J16 pins 1-2, 4-5, 7-8.

3.Insert the Skew assembly onto the PCB using 11 pin headers J16 and J17.

4.The correct orientation of the skew board is to place the side with the logo into header J17.

5.Reassemble unit.

Removal is the opposite of the above. Ensure 3 jumpers are installed in locations shown in Figure 6:

Figure 6: Skew Module

15

Image 17
Contents Models Tables ContentsIntroduction Overview Getting StartedOverview Making the Connections Setup and InstallationData Mode Configuration Transmitter Connections Connections on the Single-Port VGA/AudioCobra R1300S2 Universal Receiver Connections Connections on the single-port VGA S2Adjustment locations Video AdjustmentSolution Solutions to Common ProblemsProblem Solution Terminal Block Connection Appendix a Cabling PinoutsDB9 Video Connector Pinout Appendix B Configuration Settings Configuration Jumper Settings Appendix D Setting Sync Mode Skew Module Appendix E Skew ModuleVideo Support Technical SpecificationsPage 2900-650004 REV