8 Setup
the power consumption of the digital receiver, refer to Table 2.1.
•The wall outlet should be near the equipment. Do not run an extention lead to the unit.
•Do not expose the digital receiver to any moisture. The digital receiver is designed for use indoors only. Use dry cloth when cleaning the digital receiver.
•Place the digital receiver on a firm and level surface.
•Do not place the digital receiver close to heat emitting units or in direct sunlight, as this will impair cooling. Do not lay any objects such as magazines on the digi- tal receiver. When placed in a cabinet, make sure there is a minimum space of 10 centimetres around it. For the physical specification of the digital receiver, refer to Table 2.2.
•Protect the power cord from being walked on or pinched. If wires are exposed or cord is damaged, do not use the digital receiver and get cord replaced.
•Never open the digital receiver casing under any cir- cumstances. Warranty will be void.
•Refer all servicing to a qualified service technician.
Table 2.1: Power specification
Input voltage | 90 to 250 V AC, 50/60 Hz |
Power consumption | 37 W at maximum in operation |
| 8 W in standby |
| |
Table 2.2: Physical specification | |
|
|
Size | 430 60 265 mm |
Weight | 2.9 kg |
Operating temperature | 0 to 45 °C |
Storage relative humidity 5 to 95 %