Bassworx BA3000.1D manual Amplifier Control and Adjustments

Page 10

Amplifier Control and Adjustments

The sensitivity adjustment is designed to provide proper level matching with various brands of head units. It allows input signal to vary between 240 millivolts to 6 volts from the head unit or any other signal processor. Begin by setting the sensitivity adjustment to the "MIN" (6 volts).

Using a compact disc that you are familiar with ,turn on head unit to the 3/4 volume setting. Slowly turn up sensitivity adjustment towards the "MAX" (240 millivolts) using a flat head screw driver. Stop turning on the onset of distortion and turn back just a slight. The 3/4 volume setting is now the "maximum" volume for the head unit. The goal is to keep the level control to the lowest setting yet still have enough signal to drive the amplifier. This is done to prevent over- driving the amplifier and to keep system noise to a minimum. It is important not over drive speakers (at point of distortion) this will cause permanent damage to the speakers. Also, if the amplifier itself is over driven, it could be damaged.

1

2

3

4

5

6

7

8

9

 

 

SUBSONIC

 

 

 

 

 

SLAVE

LINE INPUT

GAIN

FILTER

BASS

L.P.F

PHASE

REMOCON

MASTER SLAVER

L

6V 0.24V

15Hz

50Hz

0dB

12dB 50Hz 250Hz

0°

180°

R

1. RCA Input Jack

2. Input Level Control

3. Low Pass Frequency

4. Subsonic Filter

5. Bass Boost Control

6. Phase Control

7. Remote Control Jack

8. Master/Slave Switch

9. Slave Input Jack

1.RCA Input Jacks - Low level, high impedance inputs. Use high quality RCA cables designed for mobile applications.

2.Input Level Control - Level match the input in accordance to your source unit. Turn clockwise to increase the level, counter clockwise to decrease. Amplifiers will run cooler and produce less system noise at lower level settings.

3.Low Pass Frequency - Adjust the crossover frequency by turning clockwise to set to a higher frequency, counter clockwise to set to a lower frequency.

4.Subsonic Filter Frequency - Adjust the subsonic filter frequency by turning clockwise to set to a higher frequency, counter clockwise to set to a lower frequency.

5.Bass Boost - Adjustment between 0-12dB Gain at 45Hz for extra bass punch.

6.Phase Control - Adjust the relative phase of the output a range of 0-180 degrees for solid bass response and accurate imaging.

7.Remote Control Jack - Used to connect remote bass level control module to the amplifier.

8.Master/Slave Switch - Select the remote level control or the on-board level control as the master control.

9.Slave Input Jack - Used to connect to another amplifier when bridging 2 amps together. The Slave mode bypasses normal input jacks and controls.

9

Image 10
Contents Model BA3000.1D Precautions Read First FeaturesCongratulations on your purchase Precautions Read First Installation Installation DiagramPower Supply Connections Recommended Power WirePower Supply Connections Single Amplifier Preamp Configuration Master / Slave Preamp Configuration Slave AmplifierSpeaker Wiring Configuration Wiring DiagramAmplifier Control and Adjustments Troubleshooting the system Symptom SolutionSpecification