Kenwood TS-B2000 Visualscan, Using Visual Scan VFO, Changing the Number of Channels to Scan

Page 78

14 SCAN

3Press [SCAN/ SG.SEL].

4The Call channel and the selected VFO frequency or memory channel are monitored alternatively.

5To stop Scan, press [SCAN/ SG.SEL] or [CLR].

VISUALSCAN

While you are receiving, Visual Scan allows you to monitor frequencies near the current operating frequency. Visual Scan graphically displays how all frequencies in the selected range are busy. You will see a maximum of 7 segments, for each frequency (channel) point that represent relative S-meter levels.

Determine the scan range by selecting the center frequency and the number of channels. The default number of channels is 61.

Using Visual Scan (VFO)

1 Select the desired band for Visual Scan.

2 Turn the Tuning control, or press Mic [UP]/ [DWN], to select the operating frequency.

This frequency will be used as the center frequency.

3Press and hold [DISP] for approximately 1 second to start Visual Scan (VFO).

The center frequency is displayed on the main frequency display and the current scanning frequency is displayed on the sub frequency display. The operating mode and the number of channels to be scanned are displayed on the main dot-matrix display. The sub dot-matrix display shows the relative S-meter level of each frequency point, vertically.

To pause Scan, press [DISP]. “P” appears on the main dot-matrix display. While the Visual Scan is paused, you can monitor the paused frequency. Press [DISP] again to resume the Visual Scan.

4To change the current scanning frequency, turn the Tuning control or press Mic [UP]/ [DWN].

The displayed frequency changes and the cursor moves.

Press [1MHz/ SEL] to make the current scanning frequency the new center frequency.

You can move the frequency using the MAIN control. If you want to revert to the original center frequency, press [FM/ AM/ NAR].

5To quit Visual Scan, press [CLR] or [SCAN/ SG.SEL].

Changing the Number of Channels to Scan

1 Press [MENU] to enter Menu mode.

2 Turn the MULTI/ CH control to select Menu No. 11.

3 Press [+] or [–]to select 31, 61 (default), 91 or

181 channels for the number of channels to scan.

4Press [MENU] to exit Menu mode.

Note:

The current frequency step of the MULTI/ CH control is used for the Visual Scan.

While performing the Visual Scan, the DUAL WATCH function {page 47} is temporarily disabled unless you are using the 144 MHz or 430 (440) MHz in FM or AM mode and the Control Band for the main transceiver.

If you start the Visual Scan from the frequency on the sub- receiver, the frequency is transferred to the main display, then the Visual Scan starts.

If you start the Visual Scan in Memory Recall mode, the memory channel frequencies will be scanned.

If the frequency range specified for Program Scan or Program VFO is narrower than the range specified for Visual Scan, the range for Program Scan or VFO will be used for Visual Scan.

Visual Scan stops when you transmit.

Depending on the transceiver conditions, Visual Scan and the S-meter level may differ.

Using Visual Scan (Memory Channel)

1 Press [MENU] to enter Menu mode.

2 Turn the MULTI/ CH control to select Menu No. 11.

3 Press [+] or [–]to select 31, 61 (default), 91 or

181 channels for the number of channels to scan.

4 Press [VFO/M] to enter Memory Recall mode.

5 Press and hold [DISP] for approximately

1 second to start Visual Scan (Memory Channel).

The center memory channel number is displayed on the main frequency display and the current scanning frequency is displayed on the sub frequency display. The operating mode of the center memory channel and the number of channels to be scanned are displayed on the main dot- matrix display. The sub dot-matrix display shows the relative S-meter level of each frequency point, vertically.

70

Image 78
Contents TS-2000 TS-2000X TS-B2000 Thank YOU FeaturesSupplied Accessories Thank YOUTypeThe Americas Models Covered by this ManualMarket Codes Type Europe E2-type SpainPrecautions Contents Contents Scan Operator ConveniencesOptional Accessories Installing OptionsMaintenance SpecificationsGround Connection InstallationAntenna Connection Lightning ProtectionDC Power Supply Connection InstallationReplacing Fuses Accessory Connections Front PanelRear Panel Your First QSO HF/ 50 MHz band Press + or -to select an HF/ 50 MHz Amateur radio bandTransmitting Your First QSO VHF/ UHF band Your First QSO VHF/ UHF band Getting Acquainted Front PanelGetting Acquainted @0CW/ FSK/ REV key @5Tuning control9LSB/ USB/ Auto key @1FM/ AM/ NAR keyMR key $3TNC Status Indicators#4QUICK Memo keys Key$6MAIN RF Gain control $4RIT/SUB control$5MANUAL BC control $7MULTI/ CH controlRear Panel 3ATT Display0AUTO 4TNC@3FINE 7DCS@0AGC @4A.NOTCH$2XIT $0ATT$1TNC $3PREMicrophone UP/ DWN keysOperating Basics Switching Power ON/OFFAdjusting Volume Selecting VFO a or VFO BSelecting a Frequency Selecting a ModeAdjusting Squelch Front Panel MeterMicrophone Gain Selecting Transmit PowerTransmitting Press PWR/ TX MoniMenu Access Menu SetupWhat is a MENU? Quick MenuGroup Menu Function Selections Default Menu ConfigurationMenu Setup ON/ OFFOFF/ H BOOST/ F Pass OFFBoost PASS/ B Boost OFFNORMAL/ Invers AutoFSK LOW/ MID/ HighSCAN/ A=B/ VFO/M CTRL/ CALL/ CLR FINE/ CH3/ CH2 CH1/ CW TuneIN/ M VFO TF-SET/ SplitAlphabetical Function List Remote Control Power ControlPower ON/ OFF SKY Command II+Basic Communications SSB TransmissionFM Transmission Narrow Bandwidth for FM Mode RX if Filter TX DeviationAM Transmission Narrow Bandwidth for AMCW Transmission TX SIDETONE/ RX Pitch FrequencyAuto ZERO-BEAT Enhanced Communications SPLIT-FREQUENCY OperationTF-SET Transmit Frequency SET Programming AN Offset FM Repeater OperationEnhanced Communications Selecting an Offset DirectionSelecting Continuous or Burst Enhanced Communications Transmitting a ToneSelecting a Tone Frequency Transmitting a 1750 Hz ToneTone FREQ. ID Scan Enhanced Communications Automatic Repeater OffsetReverse Function Automatic Simplex Check ASCPress FUNC, 6/ CTCSS/SEL FM Ctcss OperationCtcss FREQ. ID Scan FreqFM DCS Operation DCS Code ID ScanPress FUNC, / DCS/SEL Communicating Aids ReceivingSelecting Your Frequency Communicating Aids RIT Receive Incremental TuningFine Tuning AGC Automatic Gain ControlVOX VOICE-OPERATED Transmit Delay TimePress FUNC, KEY/ Delay Microphone Input LevelXIT Transmit Incremental Tuning Communicating Aids Speech ProcessorPress XIT/ ALT TX Filter Bandwidth SSB/AM Transmit InhibitChanging Frequency While Transmitting TX Equalizer SSB/FM/AMReverse Keying Weight Ratio Using Semi BREAK-IN or Full BREAK-INAuto Weighting CW BREAK-INStoring CW Messages Communicating Aids BUG KEY FunctionCW Message Memory Checking CW Messages without TransmittingFrequency Correction for CW Auto CW TX in SSB ModeChanging the Sidetone Volume Changing the Inter-message Interval TimeSUB-RECEIVER SUB-RECEIVERTX Band and Control Band SUB-RECEIVER Adjusting the SquelchSelecting a Mode for the SUB-RECEIVER Selecting a FrequencyPRE-AMPLIFIER Selecting a Transmit PowerSUB-RECEIVER Attenuator Dual WatchMemory SUB-RECEIVER Automatic Simplex Check ASCSpecialized Communications Command modeConverse mode Packet RadioA./ Canada Specialized Communications PreparationDCD Sense Press LSB/ USB/ Auto or FM/ AM/ NAR toRadio Teletypewriting Rtty Specialized CommunicationsA./ Canada ARU Region Slow Scan TV/ Facsimile AMTOR/ PacTOR/ CLOVER/ G-TOR/ PSK31DX Packet Cluster Tune Satellite OperationBasic Operation Satellite Channel Name Quick Memory in Satellite ModeUsing XIT/ RIT in Satellite Mode Checking the Uplink FrequencySSB/ FM/ AM Modes Rejecting InterferenceDSP Filters CW/ FSK ModesSetting the N.R Time Constant Auto Beat Cancel SSB/ AMSetting the N.R Level Adjustment Rejecting Interference Notch Filter SSBAttenuator Noise BlankerPRE-AMPLIFIER Rejecting InterferenceStoring Data in Memory Memory FeaturesMemory Channels Simplex ChannelsSplit-Frequency Channels Memory FeaturesMemory Recall and Scroll Memory RecallMEMORY-VFO Split Operation Memory ScrollTemporary Frequency Changes To use a memory channel for receivingMemory Features Memory Transfer Press MsVFO/ MG.SELChannel \ Channel Transfer Erasing Memory Channels Memory Features Storing Frequency RangesPress VFO/M to enter Memory Recall mode Confirming Start/End FrequenciesAlpha-numeric characters Memory Features Memory Channel NameAvailable characters using a Dtmf Mic Available charactersStoring Into Quick Memory Memory Features Memory GroupPress FUNC, MsVFO/ MG.SEL to enter Memory Group Select mode Memory Group SelectTemporary Frequency Changes Recalling Quick Memory ChannelsQuick Memory VFO Transfer Press Quick Memo MRVfoscan ScanNormal Scan Scan Type PurposeScan Programscan ProgramscanpartiallyslowedScanresumemethod Memory ScanScanhold ALL-CHANNELSCANGroupscan CallscanVisualscan Using Visual Scan VFOUsing Visual Scan Memory Channel Changing the Number of Channels to ScanScan Antenna Selection Frequency Range MHz AntennasAutomatic Antenna Tuner Main transceiver SUB-receiverAT Preset Frequency Range MHz Auto ModePresetting Operator ConveniencesPress and hold USB/ LSB/ Auto + to turn the transceiver on Mode Morse Code OutputBeep Function Channel No DataCall Channel DtmfTransmitting Dtmf Memory Channel Data HF RX AntennaLinear Amplifier Control Dtmf Tone Time LengthPF KEY Lock FunctionsMonitor Microphone PF KeysSeperate Speaker Output TIME-OUT TimerRX DSP Equalizer Meter SquelchTransverter TX PowerTNC TX MonitorSetting UP Using Quick TransferQuick Data Transfer Communication Parameters Computer ControlRemote Microphone Controller FuncWireless Remote Control Control OperationTone SEL SKY Command II + Diagram TS-2000 Transporter SetupTM-D700A Commander Setup On the TS-2000 Transporter Starting Sky Command II+ operationOn the TM-D700A Commander Mic Key FunctionOperator Conveniences Using TH-D7A AS a Commander TS-2000X Transporter SetupTH-D7A Commander Setup Mode PowerUP/ DWN RITOperator Conveniences Using Another TS-2000 AS a Commander TS-2000 Commander SetupStarting Sky Command ll+ operation CROSS-BAND Repeater Using a Separate TransporterLOCKED-BAND Repeater Hang Time for Repeater FunctionChecking Messages Recording MessagesMessage Playback Press 1/ CH1/REC, 2/ CH2/REC, orErasing a Recorded Message Changing Playback VolumeSending Messages Changing Inter-message Interval TimeVOICE1 CallMenu VOICE2Partial Reset Microprocessor ResetInitial Settings Full ResetCompatible Transceiver Connecting Peripheral EquipmentComputer PinHF Linear Amplifier Connecting Peripheral EquipmentRtty Equipment Antenna TunerMCP and TNC Pin No FunctionEXT.CONT connector Pin No Function DRU-3A Digital Recording Unit Installing OptionsRemoving the Bottom Case VS-3 Voice Synthesizer UnitInstalling Options MB-430 Mobile BracketRC-2000 Remote Panel Troubleshooting Lithium BatteryGeneral Information Troubleshooting TroubleshootingREV , or FM/ AM/ NAR to select Press LSB/ USB/ Auto , CW/ FSKAre totally Selected Press LSB/ USB/ Auto or FM/ AMOFF AGC TX Signal HarmonicsOperation Notices Internal BeatsMC-52DM Optional AccessoriesDRU-3A PG-2ZSpecifications GeneralSpecifications SSB/ CW/ FSK/ FMSSB TS-2000 TS-2000X TS-B2000 ~ 1.705 MHz 705 ~ 24.5 MHz ∝V or less 24.5 ~ 30.0 MHz50.0 ~ 54.0 MHz SSB/ CW/ FSK/ AM Reset button AppendixTS-B2000 Front Panel BUILT-IN TNC Command List Command Short Default Parameter DescriptionAppendix Frack ResetFlow ON/ OFF HbaudTrace OFF ON/ OFF TxdelaySlottime Tries TRICOM COM ConnectorHardware Description TXD GNDAlphabetical Commands Appendix Computer Control CommandsError Messages TerminatorPC Control Command Tables TX-AT Thru116 ASC on117 Sets or reads the Packet Cluster Tune function on Parameters 119 120 FunctionAppendix 121122 123 124 125 XIT OFF, 1 XIT on126 127 Monitor OFF128 129 NB OFF130 131 132 PM OFF133 134 135 Trace REV. OFF, 1 Trace REV on136 SUB TF-W OFF137 138 139 Tone on140 141 Index Index
Related manuals
Manual 10 pages 5.52 Kb