Kenwood TM-D700A, TM-D700E instruction manual Scan Type Scan Range

Page 52

SCAN

Scan is a useful feature for hands-off monitoring of your favorite frequencies. Becoming comfortable with all types of Scan will increase your operating efficiency.

9

Stop

This transceiver provides the following types of scans plus Visual Scan {page 47}. Visual Scan graphically and simultaneously shows how frequencies in a specific range are busy.

Scan Type

Scan Range

VFO Scan

All frequencies tunable on the band

Memory Scan

Frequencies stored in the memory

channels

 

 

Frequencies stored in the memory

Group Scan

channels which belong to the

 

specified group

Program Scan

All frequencies in the range

selected on the band

 

MHz Scan

All frequencies within a 1 MHz range

 

 

Call/VFO Scan

Call channel plus the current VFO

frequency

 

Call/Memory Scan

Call channel plus the selected

memory channel

 

Note:

Adjust the squelch level before using Scan. Selecting a squelch level too low could cause Scan to stop immediately.

While using CTCSS or DCS, Scan stops for any signal received; however, you will hear audio only when the signal contains the same CTCSS tone or DCS code that you selected.

When using S-meter Squelch, Scan stops when the received signal strength matches or exceeds the S-meter setting. Scan resumes 2 seconds after the signal level drops below the S-meter setting.

Pressing and holding Mic [PTT] causes Scan to temporarily stop if it is functioning on a non TX band.

Starting Scan switches OFF the Automatic Simplex Check.

46

Image 52
Contents TM-D700A Thank YOU FeaturesModels Covered by this Manual When condensation occurs inside the transceiver One or more of the following statements may be applicableContents Selecting the Number of Channels Using Visual Scan Setting Scan Limits Using Program ScanRecalling the Call Channel Reprogramming the Call Channel Locking Out a Memory ChannelChanging MULTI-FUNCTION Squelch Hang TimeSupplied Accessories Conventions Followed in this ManualMain Unit Installation Mobile InstallationPreparation Front Panel Installation Slide the front panel down until its locking tab clicksFixed Station Installation Modular Plug Cable ConnectionDC Power Cable Connection Mobile OperationFixed Station Operation PS-33 20.5 A, 25% duty cycleTransceiver 15 a Supplied Accessory 20 a DC Power Cable Antenna ConnectionReplacing Fuses Fuse Location Fuse Current RatingExternal Speakers Accessory ConnectionsMicrophone Your First QSO Ew wew wGetting Acquainted Front Panel3SQL control Main UNIT- Rear Main UNIT- FrontGPS jack Microphone Indicators Basic Transceiver Modes Button Function Display Band a & B TX Band and Control BandTX Band Control BandMIC Keypad Direct Entry MC-53DM only Switching Power ON/OFF Adjusting VolumeSwitch on the DC power supply Operating BasicsAdjusting Squelch Selecting a FrequencyWhen you finish speaking, release Mic PTT Selecting Output PowerTransmitting Menu Access Press MNU to enter Menu modeMenu SET-UP Press c/ d to select the appropriate level 1 No Press OKMenu Configuration Level Selections DefaultAuto PM Channel Store Channel DisplayMemory Channel Lockout Memory channel name See reference Number StoreVisual Scan Automatic Power Off APO Remote ControlMic PF Key See reference Mic MR Key Mic VFO Key See referenceMy call sign See reference Color for call sign WhiteMessage See reference Color for message RSV report See reference Color for RSV reportCommander call sign See reference Transporter call sign Sky Command modeStatus text transmit rate See reference Packet path See referenceOperating Through Repeaters Offset Programming FlowProgramming Offset Selecting Offset DirectionSelecting Offset Frequency Press c / d to select Radio 1-, then pressActivating Tone Function Selecting a Tone FrequencyPress Tone to activate the Tone function Press F, T.SELAutomatic Repeater Offset A. and Canada versionsTransmitting a 1750 Hz Tone Reverse Function Press REV to switch the Reverse function on or OFFAutomatic Simplex Check ASC Tone FREQ. ID Press Scan to activate the Tone Freq. IDSimplex & Repeater or ODD-SPLIT Memory CHANNEL? Memory ChannelsParameter Simplex Odd-split Press M.IN 1 s Storing ODD-SPLIT Repeater FrequenciesSelect the desired transmit frequency Press M.IN Select band a or B Press MR to enter Memory Recall mode Press MHz Tuning control+ Power onRecalling a Memory Channel Clearing a Memory ChannelTurn the Tuning control to select the first digit Naming a Memory ChannelPress a Repeat steps 6 and 7 to enter up to 8 digitsCall Channel Recalling the Call ChannelReprogramming the Call Channel Press VFOMEMORY-TO-VFO Transfer Channel DisplayPartial or Full RESET? ParameterBand B 440.000 MHzProgrammable Memory PM Programmable InformationApplication Examples Situationit tiStoring in PM Channels Recalling a PM ChannelPress PM+ Power on PM Channel ResetAuto PM Channel Store Scan Scan Type Scan RangeMode 1 31 ch Mode 2 61 chVisual Scan Selecting the Number of ChannelsPress F, Visual to start Visual Scan Using Visual ScanTo quit Visual Scan, press ESC Time-Operated mode Carrier-Operated modeSeek mode Selecting Scan Resume MethodVFO Scan Memory ScanPress VFO 1 s Select band a or BPress MHz Tuning control 1 s Group ScanLocking Out a Memory Channel To quit Group Scan, press MHz againProgram Scan Setting Scan LimitsSelect the desired frequency as the lower limit Press F Using Program Scan Select the appropriate bandTo quit Program Scan, press VFO again To quit MHz Scan, press MHz againCALL/VFO Scan CALL/MEMORY ScanTo quit Call/VFO Scan, press Call again To quit Call/Memory Scan, press Call againUsing Ctcss Continuous Tone Coded Squelch System CtcssPress the left or right Band SEL to select band a or B Press Tone to activate the Ctcss functionCtcss FREQ. ID Press Scan to activate the Ctcss Freq. IDDigital Code Squelch DCS Using DCSPress Tone to activate the DCS function DCS Code ID Press Scan to activate the DCS Code IDDtmf Monitor Manual DialingFreq. Hz 1209 1336 1477 1633 Turn the Tuning control to select a character Automatic DialerStoring a Dtmf Number in Memory Repeat steps 4 and 5 to enter up to 8 digitsSelecting TX Speed Transmitting a Stored Dtmf NumberSelecting Pause Duration Programmable Function PF Keys PF PF1MR PF2 VFO PF3Press VFO Press Mic Enter Auxiliary FunctionsPress the numeric keys in sequence on the keypad Changing Frequency Step Size Programmable VFOPress VFO Press F, Step Press c/ d to select the desired step sizeDisplay Dimmer Auto Dimmer Change Display Contrast AdjustPOSITIVE/ Negative Reversal Blanking a Band Display Automatic Band Change A.B.CPWR switch MHz SQL controls VOL controls Press F, MHz to switch the function on or OFFTransceiver Lock Changing MULTI-FUNCTION Button LabelsMeter Squelch Squelch Hang TimeChanging Beep Volume Switching FM/AM ModeKEY Beep ON/ OFF Advanced Intercept Point AIPTIME-OUT Timer TOT Automatic Power OFF APODisplay Demonstration POWER-ON MessageRepeat steps 3 and 4 to enter up to 8 digits Changing Speaker Configurations Connection Mode Band a Band BSpeaker Mute Changing TX/RX Deviation TM-D700E onlyMicrophone Control with MC-53DM only Wireless Remote Control U.S.A./ Canada only PreparationAccess Menu 1-A-3 Control and select on Control OperationSelect the receive frequency on band B UHF Digits Enter or VFO UP/ DownSKY Command 2 U.S.A./ Canada only FreqConnecting the Transporter with the HF Transceiver TM-D700APreparation Flow 17 rOn Commander Programming Call SignsProgramming a Tone Frequency On TransporterMic Key Function RIT ON/ OFF XIT ON/ OFFT y Repeater Function U.S.A./ Canada only VS-3 Voice Synthesizer Optional Band SELOptional Accessories PS-33 SP-50B VS-3 VC-H1PG-2N PG-3B PG-4X PG-5A MC-45 MC-53DM MC-80 MJ-88 MJ-89Installing Options Installing the PG-4X Extension Cable KITRemove the 6 screws from the lower cover of the main unit Replace the lower cover 6 screwsConnections Using One Set of PG-4X Kit Connections Using Two Sets of PG-4X KitsMaintenance ServiceService Note CleaningTroubleshooting Problem Probable Cause Corrective ActionCOM Port Specifications VHF Band UHF BandTransmitter Sub VHF or UHF bandIndex