Kenwood TM-D700A, TM-D700E Automatic Dialer, Storing a Dtmf Number in Memory

Page 66

AUTOMATIC DIALER

If you use the 10 dedicated memory channels to store DTMF numbers, you need not remember a long string of digits.

Storing a DTMF Number in Memory

Note: Audible DTMF tones from other transceivers near you (or from your own speaker) may be picked up by your microphone. If so, you may fail to correctly program a DTMF number.

1 Press [MNU] to enter Menu mode.

2 Select Menu 1–5–1 (STORE), then press [OK].

3 Press [c]/ [d] to select from channels 0 to 9, then press [OK].

• The display for entering a memory name

6Repeat steps 4 and 5 to enter up to 8 digits.

Switches among the sets of alphanumeric characters, accented letters (TM-D700E only), and special ASCII characters.

Switches between

Cancels Memory

small and capital

Name Entry.

letters.

 

Deletes the digit at

Causes the cursor

which the cursor is

to move backward.

blinking.

 

Inserts the

 

 

 

 

 

 

 

 

Clears all digits

 

 

 

 

 

 

 

 

currently selected

 

 

 

 

 

 

 

 

and backs the

character.

(left BAND cursor to the first

 

 

SEL)

digit.

 

 

 

 

 

 

 

 

 

7Press [OK].

• The cursor moves to the start of the next field.

12

appears; the first digit blinks.

To skip naming the channel, press [OK] again. You can jump to step 8.

4Turn the Tuning control to select a character.

You can enter alphanumeric characters plus special ASCII characters.

5Press [a].

The cursor moves to the next digit.

8Press the keys in sequence on the Mic keypad to enter a DTMF number with up to 16 digits.

You may turn the Tuning control then [a] to select each digit. Select a space if you want to include a pause.

9Press [OK] to complete the programming.

10Press [MNU] to exit Menu mode.

You can confirm the stored DTMF number by using steps 1 to 3.

The keypad on the MC-53DM also is available to enter alphanumeric characters in step 4. See page 18.

60

Image 66
Contents TM-D700A Features Thank YOUModels Covered by this Manual When condensation occurs inside the transceiver One or more of the following statements may be applicableContents Recalling the Call Channel Reprogramming the Call Channel Selecting the Number of Channels Using Visual ScanSetting Scan Limits Using Program Scan Locking Out a Memory ChannelChanging MULTI-FUNCTION Squelch Hang TimeSupplied Accessories Conventions Followed in this ManualMobile Installation Main Unit InstallationPreparation Front Panel Installation Slide the front panel down until its locking tab clicksFixed Station Installation Modular Plug Cable ConnectionDC Power Cable Connection Mobile OperationFixed Station Operation PS-33 20.5 A, 25% duty cycleReplacing Fuses Transceiver 15 a Supplied Accessory 20 a DC Power CableAntenna Connection Fuse Location Fuse Current RatingAccessory Connections External SpeakersMicrophone Your First QSO Ew wew wGetting Acquainted Front Panel3SQL control Main UNIT- Front Main UNIT- RearGPS jack Microphone Indicators Basic Transceiver Modes Button Function Display TX Band Band a & BTX Band and Control Band Control BandMIC Keypad Direct Entry MC-53DM only Switch on the DC power supply Switching Power ON/OFFAdjusting Volume Operating BasicsAdjusting Squelch Selecting a FrequencySelecting Output Power When you finish speaking, release Mic PTTTransmitting Menu SET-UP Menu AccessPress MNU to enter Menu mode Press c/ d to select the appropriate level 1 No Press OKMenu Configuration Level Selections DefaultMemory Channel Lockout Auto PM Channel StoreChannel Display Memory channel name See reference Number StoreMic PF Key See reference Mic MR Key Visual Scan Automatic Power Off APORemote Control Mic VFO Key See referenceMessage See reference Color for message My call sign See reference Color for call signWhite RSV report See reference Color for RSV reportStatus text transmit rate See reference Commander call sign See reference Transporter call signSky Command mode Packet path See referenceOperating Through Repeaters Offset Programming FlowSelecting Offset Frequency Programming OffsetSelecting Offset Direction Press c / d to select Radio 1-, then pressPress Tone to activate the Tone function Activating Tone FunctionSelecting a Tone Frequency Press F, T.SELAutomatic Repeater Offset A. and Canada versionsTransmitting a 1750 Hz Tone Press REV to switch the Reverse function on or OFF Reverse FunctionAutomatic Simplex Check ASC Tone FREQ. ID Press Scan to activate the Tone Freq. IDMemory Channels Simplex & Repeater or ODD-SPLIT Memory CHANNEL?Parameter Simplex Odd-split Storing ODD-SPLIT Repeater Frequencies Press M.IN 1 sSelect the desired transmit frequency Press M.IN Recalling a Memory Channel Select band a or B Press MR to enter Memory Recall modePress MHz Tuning control+ Power on Clearing a Memory ChannelPress a Turn the Tuning control to select the first digitNaming a Memory Channel Repeat steps 6 and 7 to enter up to 8 digitsReprogramming the Call Channel Call ChannelRecalling the Call Channel Press VFOMEMORY-TO-VFO Transfer Channel DisplayBand B Partial or Full RESET?Parameter 440.000 MHzProgrammable Memory PM Programmable InformationApplication Examples Situationit tiStoring in PM Channels Recalling a PM ChannelPM Channel Reset Press PM+ Power onAuto PM Channel Store Scan Scan Type Scan RangeVisual Scan Mode 1 31 chMode 2 61 ch Selecting the Number of ChannelsUsing Visual Scan Press F, Visual to start Visual ScanTo quit Visual Scan, press ESC Seek mode Time-Operated modeCarrier-Operated mode Selecting Scan Resume MethodPress VFO 1 s VFO ScanMemory Scan Select band a or BLocking Out a Memory Channel Press MHz Tuning control 1 sGroup Scan To quit Group Scan, press MHz againSetting Scan Limits Program ScanSelect the desired frequency as the lower limit Press F To quit Program Scan, press VFO again Using Program ScanSelect the appropriate band To quit MHz Scan, press MHz againTo quit Call/VFO Scan, press Call again CALL/VFO ScanCALL/MEMORY Scan To quit Call/Memory Scan, press Call againPress the left or right Band SEL to select band a or B Using CtcssContinuous Tone Coded Squelch System Ctcss Press Tone to activate the Ctcss functionCtcss FREQ. ID Press Scan to activate the Ctcss Freq. IDUsing DCS Digital Code Squelch DCSPress Tone to activate the DCS function DCS Code ID Press Scan to activate the DCS Code IDManual Dialing Dtmf MonitorFreq. Hz 1209 1336 1477 1633 Storing a Dtmf Number in Memory Turn the Tuning control to select a characterAutomatic Dialer Repeat steps 4 and 5 to enter up to 8 digitsTransmitting a Stored Dtmf Number Selecting TX SpeedSelecting Pause Duration MR PF2 Programmable Function PF KeysPF PF1 VFO PF3Auxiliary Functions Press VFO Press Mic EnterPress the numeric keys in sequence on the keypad Press VFO Press F, Step Changing Frequency Step SizeProgrammable VFO Press c/ d to select the desired step sizeAuto Dimmer Change Display Contrast Adjust Display DimmerPOSITIVE/ Negative Reversal Blanking a Band Display Automatic Band Change A.B.CTransceiver Lock PWR switch MHz SQL controls VOL controlsPress F, MHz to switch the function on or OFF Changing MULTI-FUNCTION Button LabelsMeter Squelch Squelch Hang TimeKEY Beep ON/ OFF Changing Beep VolumeSwitching FM/AM Mode Advanced Intercept Point AIPTIME-OUT Timer TOT Automatic Power OFF APOPOWER-ON Message Display DemonstrationRepeat steps 3 and 4 to enter up to 8 digits Speaker Mute Changing Speaker ConfigurationsConnection Mode Band a Band B Changing TX/RX Deviation TM-D700E onlyMicrophone Control with MC-53DM only Wireless Remote Control U.S.A./ Canada only PreparationSelect the receive frequency on band B UHF Access Menu 1-A-3 Control and select onControl Operation Digits Enter or VFO UP/ DownSKY Command 2 U.S.A./ Canada only FreqConnecting the Transporter with the HF Transceiver TM-D700APreparation Flow 17 rProgramming a Tone Frequency On CommanderProgramming Call Signs On TransporterMic Key Function RIT ON/ OFF XIT ON/ OFFT y Repeater Function U.S.A./ Canada only VS-3 Voice Synthesizer Optional Band SELPG-2N PG-3B PG-4X PG-5A Optional AccessoriesPS-33 SP-50B VS-3 VC-H1 MC-45 MC-53DM MC-80 MJ-88 MJ-89Remove the 6 screws from the lower cover of the main unit Installing OptionsInstalling the PG-4X Extension Cable KIT Replace the lower cover 6 screwsConnections Using One Set of PG-4X Kit Connections Using Two Sets of PG-4X KitsService Note MaintenanceService CleaningTroubleshooting Problem Probable Cause Corrective ActionCOM Port Specifications VHF Band UHF BandTransmitter Sub VHF or UHF bandIndex