Network Technologies RACKMUX-T15 Default Configuration, Disp Setup Menu F2 General Setup Menu

Page 12

NTI RACKMUX RACKMOUNT ANSI TERMINAL DRAWER

2.1.4 Default Configuration

The terminal is delivered pre-configured with the following settings suitable for most RS232 serial console connections at 9600 baud using VT-100 emulation.

Disp SETUP Menu

F2 General SETUP Menu

Columns = Econ-80

Personality = VT 100

Cursor = Blink Block

Enhance = On

Screen Saver = Off

Status Line = Standard

Lines = 24

Scroll Speed = Jump

Background = Dark

Auto Scroll = On

Page Length = 1 x Lines

End of Line Wrap = On

Auto Page = Off

Rcvd CR = CR

Width change clear = Off

Monitor = Off

ANSI Reverse = Off

Attribute = Char

Display= LCD

 

F4 Comm SETUP Menu

F5 Misc SETUP Menu

Baud rate = 9600

Wprt Intensity = Dim

Data / Stop Bits = 8/1

Wprt Reverse = Off

Parity = None

Wprt Underline = Off

Rcv Hndshake = Xon/Xoff

Block End = US/CR

Xmt Hndshake = Xon/Xoff

Ptr Baud rate = 38400

Comm Mode = FDX

Ptr Data/Stop Bits = 8/1

XPC Handshake = On

Ptr Parity = None

Printer Selection = Off

Ptr Rcv Hndshake = Xon/Xoff

Multiple Sessions = Off

Ptr Xmt Hndshake = Xon/Xoff

Ethernet Mode = Off

Ptr Rcv = Off

Auto Connect = Off

 

F3 Keybd SETUP Menu

Keyclick = Off

Key Repeat = 5

Xmt Limit = None

Margin Bell = Off

Language = US

Keycode = ASCII

NRC = Off

Bell Volume = 2

NUM Start = Off

DEL Keypad = Dot/Del

F9 Lan Setup Menu

Local IP Address = {blank} Netmask = {blank} Gateway = {blank}

Remote IP 0..B Address ={blank} Port 0...B = 23

Term Type = vt100 Ethernet Node ID = (default}

For use with an Ethernet connection the following parameters need to be configured:

Display Setup (F1 in setup mode)

Page Length = 1*Lines (only required if ‘Multiple Sessions=On’)

Communications Setup (F4 in setup menu) Multiple Sessions = Off or On

Ethernet Mode = On Auto Connect = Off or On

‘Multiple Sessions=On’ should be set if multiple telnet sessions are required.

‘Auto Connect=On’ is used to prevent the need to press return to establish a telnet connection.

LAN Setup (F9 in setup mode)

Local IP Address = IP address of the terminal

Netmask = Netmask value for the network

Gateway = gateway address if required by the network

Remote IP 0 Address = IP address of first server Port = 23

Remote IP 1 Address = IP address of second server Port = 23

….

Remote IP B Address = IP address of twelfth server Port = 23

Term Type = Same as personality specified in General Setup menu

Ethernet Node ID = leave at default value

Note: If only one host is being connected to, all twelve Remote IP addresses and ports should be set to the same value.

Note: Eight separate telnet sessions are allowed if any columns other than Econ-80 is selected in Terminal Display Set- up. If Econ-80 is selected, the Multiple Sessions option allows twelve concurrent telnet sessions to be used.

8

Image 12
Contents RACKMUX-T15 Trademark Table of Contents Table of Figures Features IntroductionMultiple RS-232 Emulations CompatibilityMaterials OptionsMaterials Supplied with this kit Features and Functions Installation Rack Mounting InstructionsStandard Rack Optional Telco 2-Post Mounting Mount to Telco post with optional mounting bracketsConnect The Cables Connect a CPU to the RackmuxPower Up The Terminal Using the RackmuxHow To Setup The Terminal Default Configuration Disp Setup Menu F2 General Setup MenuF4 Comm Setup Menu F5 Misc Setup Menu F3 Keybd Setup MenuF1- Disp Setup Menu F2- Genrl Setup MenuChanging The Operating Parameters F3- Keybd Setup Menu F4- Comm Setup MenuPrinter F5- Misc Setup Menu F7- FKeys SET-UP Definition Setup MenuF6-Tabs SET-UP Menu Printer RCV ON/OFFF9- Lan Setup Menu F8- Ansbk SET-UP MenuF10- Colr1 Set-up Menu Programmable KeysColor Association = OFF/ON Color Setup Menu F11- Colr2 Set-up MenuAttribute = Bold/Blink OptionColor Palettes Palette Display Attribute Foreground Color Background ColorColor Palettes Contd Local Keyboard Commands Command Enhanced PCConnector PIN Assignment Pin Signal Mnemonic DirectionPin Signal Direction Command Guide Commands Supported in Ascii PersonalitiesSame WyseNative Mode Wyse Select bell volumeStop parity word Key/fkey DELSequence DEL Key/fkey Sequence Sequence DELESC . cursor1 Message CRESC a mf attr AttrFcolor Bcolor mapCol Line colCcc C Editing Contd Clearing DataSending data Print Functions Character SetsSet Pp bb...bbVariable Values for Commands Function Key Unshifted Shifted FunctionKey Unshifted Shifted Handshaking ProtocolSpace DefinitionMax Maximum Speed Screen Area*eBell Volume Function KeyPalette Color Pallette Parity BitsAnsi Command Guide VT100, VT220 and Console Ansi Command GuideWnd/page Window or Write-Protected Display AttributeCharacter Set Selection ESC Ps finalSame Label assignedFinal character Values for Ps aboveCharacter Attribute Ps FunctionValues for Psn in table on Editing FunctionsVT100, VT220 Console Ansi Editing Functions Contd Clear Key LockShifted function key Unshifted function key Key ValueValues of Fn for Numeric Keypad keys Numeric Value KeypadMore Terminal Control Commands Terminal ResetsAuxiliary Keypad Modes Transmission/Printer ControlVT52 Command Guide Command VT52See table below for values of Ps Keyboard LanguageUsing Printer Server in Ethernet Terminal Basic SetupSetup for LPD IntroductionLPD printing Setup for Tftp Tftp PrintingON-SCREEN Display OSD Standard ControlsOSD Control Menu OSD Main MenuBrightness/Contrast Menu Color MenuPosition Menu Setup Menu OSD Image can be moved to different points on the displayKeyboard Functions Function Key OperationNumber Pad Keys of the Number PadOther Uses of the Function Key Numeric Keypad OptionPin assignment at Wire Color Standard End Crossed End CPU-TO-RACKMUX Ethernet Crossover CableStandard Crossed End Crossover Cable DC Power Option Rackmux with DC Power optionDimensional Drawings Frequently Asked Questions Questions and AnswersTechnical Specifications Troubleshooting Warranty InformationIndex