Agilent Technologies 5964-8134 manual Table A-2. Supplemental Characteristics

Page 21

Table A-2. Supplemental Characteristics

Isolation to Ground:

Measurement Ranges

Average Measurement Resolution

THD (for a fundamental amplitude 5% of full scale):

Measurement System

Measurement Source Synchronization:

Measurement Buffer Length:

Measurement/Generation Synchronization:

Measurement Acquisition Sampling Rate Range:

Voltage/Current Digitization Accuracy:

Voltage/Current Digitization Resolution:

Harmonic Measurement Time (amplitude):

AC Voltage:

DC Voltage:

Current:

rms Voltage: rms Current:

Meas:Curr:Harm? <n> Meas:Array:Curr:Harm?

300 Vrms/425 Vdc

0300 Vrms

±425 V

±80 A peak (high range)

±8 A peak (low range)

13 A rms max. continuous

10mV 2 mA

5% of reading + 0.1%

<100 ns

4096 points

50 μs

25250 μs

12 bits

16 bts

400ms

10 s

21

Image 21
Contents Addendum Contents Agilent Option 022 Description Agilent Dual Power Analyzer DescriptionFront Panel Menus Additions Scpi Programming Commands AdditionsPower Analyzer input. Connector plug is removable InstallationTurn the unit off before connecting any wires Rear Panel ConnectionsMeasurement Cable Connections External Shunt Line and Load Connections Setting the Output Frequency Modulation Check the External Current Shunt SettingFront Panel Programming To set the output frequency modulationMaking Power Analyzer Input Measurements Using the Front Panel Display with the Power Analyzer InputTo select the measurement source Use the Input menu for selecting the frequency sourceMEASureTVOLt? FETChTVOLt? Additional Measurement CommandsMEASureVOLTageRANKed? FETChVOLTageRANKed? MEASureTVOLtABSolute? FETChTVOLtABSolute?Query Syntax Parameters Examples Parameters ExamplesAdditional Sense Commands SENSeNSELectSENSeFREQuencySOURce FMDEViation Additional Frequency Modulation CommandsFMFREQuency RST Value UnitCommand Syntax Parameters Examples Additional Calibration CommandsCALibrateVOLTageEXTernal CALibrateCURRentEXTernalBehavior Differences of Existing Scpi Commands UPS Transfer Time Measurement Programming ExampleUsing the Power Analyzer Input with the GUI Making a MeasurementPrograms Agilent AC Source AC Source GUI Making a Voltage Phase Difference Measurement Modulating the Output Frequency Performing a Transfer Time TestTable A-1. Performance Specifications Power Analyzer Input SpecificationsTable A-2. Supplemental Characteristics Verification and Calibration for Option 020/022 Equipment RequiredTable B-1. Equipment Required Test Set up Verification ProcedurePower Analyzer Current Measurement Accuracy Power Analyzer Voltage Measurement AccuracyEnable Calibration Mode Calibration ProcedureDisplay Command Function Summary of Front Panel Calibration MenuCAL Save

5964-8134 specifications

Agilent Technologies 5964-8134 is an advanced analytical instrument designed for versatile applications in laboratory settings. It serves as a crucial component for professionals working in fields such as forensic science, environmental testing, and pharmaceutical analysis.

One of the primary features of the 5964-8134 is its exceptional chromatographic performance. The device employs sophisticated separation techniques, utilizing a high-efficiency column that enhances the resolution of complex mixtures. This capability allows scientists to identify and quantify trace levels of compounds in samples with high precision.

Equipped with a state-of-the-art detector, the 5964-8134 offers a broad dynamic range to accommodate various analyte concentrations. This feature ensures that both minor and major components can be accurately measured, making it ideal for applications involving diverse sample matrices. The integrated software provides users with easy access to data analysis tools, enabling seamless interpretation of results.

The 5964-8134 is built on cutting-edge technology, including advanced mass spectrometry which enhances its sensitivity and specificity. This technology enables the detection of low-abundance compounds in complex samples, providing insights that would be difficult to obtain using traditional methods. Additionally, the instrument supports multiple ionization techniques, allowing users to tailor the analysis to specific requirements of their project.

Another characteristic of the Agilent 5964-8134 is its user-friendly interface. The equipment is designed with the operator in mind, featuring intuitive controls and a touchscreen display that promotes ease of use. This design minimizes the learning curve for new users, enabling efficient operation and streamlined workflow in busy laboratory environments.

Moreover, the 5964-8134 ensures robust performance with its advanced temperature control and reliable fluidic systems. These features contribute to improved reproducibility and stability during analyses, which are critical in achieving consistent results across experiments.

With its combination of high performance, cutting-edge technologies, and user-centric design, Agilent Technologies 5964-8134 stands out as a leading choice for professionals seeking reliable and accurate analytical solutions. As laboratories continue to demand innovative instruments that push the boundaries of research capabilities, the 5964-8134 proves to be an essential tool in scientific discovery and analysis.