B&B Electronics 485DSS manual Select State

Page 15

in the address field specifies all 485DSS's on the network. This command temporarily turns off (disconnect) the RS-232 port from the network while transmitting the reply message.

The reply message transmitted by the 485DSS consists of six ASCII characters. The first character is the acknowledge character, an upper case "A" (decimal 65). The second and third characters represent the hexadecimal address of the 485DSS that sent the message. The address range is from 0 to 255 (HEX "00" to "FF"). The fourth character indicates the select state of 485DSS, a "0" (decimal 48) indicates the RS-232 port does not have a connection (not selected) to the network and a "1" (decimal 49) indicates the RS-232 port has a connection (selected) to the network. The fifth character indicates the state of the CTS handshake input line on pin 5 of the RS-232 port connector. A "0" (decimal 48) indicates a low state on the CTS input pin, and a "1" (decimal 49) indicates a high state on the CTS input pin. The sixth character is the end of message character, a carriage return (decimal 13).

Reply Syntax: A ___ ___ ___ ___ cr

End of message char.

Handshake input state.

Select State.

Least signf. address character.

Most signf. address character.

Start of message character.

When this command contains a specific address, the 485DSS whose address matches the command address will wait for twenty milliseconds before transmitting the reply message. If the command uses the broadcast characters to receive status from all 485DSS's on the network each 485DSS will delay transmitting its reply based on its address. The amount of delay is equal to the unit's address in decimal multiplied by twenty milliseconds then add an additional 20 milliseconds.

12

485DSS3298 Manual

B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350

PH (815) 433-5100 -- FAX (815) 434-7094

Image 15
Contents Electronics Mfg. Co. Inc Designed and Manufactured Ottawa, IllinoisInternet Table of Contents Appendix C Cable Charts Hardware Introduction ChecklistSpecifications Port ConfigurationRS-485/422 Port RS-232 Port RS-422/485 Port Terminal Block Signal Description DirectionWire Mode RS-422/485 WiringComponent Values For Send Data Timing RS-485 Wiring Diagram Wire Mode RS-422 Wiring Diagram RS-485 and RS-422 Termination Power SupplyOperation Distributed Smart Switch Commands Communication ConfigurationOn Command Command StringStatus Request Command OFF CommandSelect State ACK Setting the 485DSS Address Address SwitchDIP Switch Binary File Transfer Software Description Hard Drive InstallationType CD\485DSS\PASCAL and press the Enter key Running Demonstration ProgramDecimal to HEX to Ascii Conversion Table Appendix a Ascii Character CodesSymbol Appendix B Decimal/Hexadecimal/ConversionsDec/Hex Conversions Decimal Hexadecimal Decimal to Hexadecimal Conversion Hexadecimal to Decimal Conversion485DSS Appendix C Cable ChartsChart 1. IBM PC DB25 Connector to 485DSS RS-232 DTE Port RS-232 DTE Port DB25 Connector DirectionDirection Terminal Blocks RS-485/422Class a Equipment