STEP 4 AUTO CALIBRATION

Once the treadmill is plugged in, you need to perform an Auto Calibration to assure maximum performance.

MODELS T9300, T9500HRT, T9600HRT & T9600HRT Comfort:

DO NOT STAND ON THE BELT WHEN PERFORMING THE AUTO-CALIBRATION

You need to access User Engineering Mode to run the Auto Calibration. To access this mode, please hold down SPEED DOWN and SELECT for 5 seconds. When in the User mode, "USEr" displays in the center window. To access the data press the ELEVATION keys until "Auto" appears in the center window. Press Start to select this function.

To begin auto-cal, press START. The treadmill will run through minimum and maximum speed and maximum incline. This will take 3-5 minutes. Let the treadmill perform this complete function before exiting the Engineering Mode.

Elevation A/D or Elevation in % appears in the left window. PWM value or Speed appears in the right window. "End" will appear in the center window when the auto-calibration is complete. When Auto-Calibration is complete, it will take about 30 seconds to go to 0 elevation and return to the start-up screen with P1 showing in the function window.

MODELS T9700S, T9700HRT & T9700 Runner:

DO NOT STAND ON THE BELT WHEN PERFORMING THE AUTO-CALIBRATION

You need to access User Engineering Mode to run the Auto Calibration. To access this mode, please hold down SPEED DOWN and SELECT for 5 seconds. When in the User mode, "User Mode" appears in the alphanumeric window. To access the data press the ELEVATION keys until "Auto-Cal" appears. Press Start to select this function.

To begin auto-cal, press START. The treadmill will run through minimum and maximum speed and maximum incline. This will take 3-5 minutes. Let the treadmill perform this complete function before exiting the Engineering Mode.

Elevation A/D or Elevation in % appears in the left window. PWM value or Speed appears in the right window. "Cal Passed" will appear in the alph-numeric window when the auto-calibration is complete. The treadmill will come to a complete stop and return to the start-up screen in the alphanumeric window.

MODEL T9200:

DO NOT STAND ON THE BELT WHEN PERFORMING THE AUTO-CALIBRATION

Hold the Elevation Up and Speed Down buttons for 5 seconds. The console will beep 5 times and a number will appear in the window. Shortly thereafter, EnG1 will appear in the window. Press the Elevation Up or Speed Up to EnG4

Press Start. The treadmill will calibrate itself. It will take 3-5 minutes. When the Auto Calibration is complete "END" will flash in the window. Wait 10 seconds.

Remove the Safety Key. Then, put the Safety Key in place to use the treadmill.

7

Image 7
Contents S e m b l y G u i d e S e m b l y I d e Parts BOX Yellow BAG Orange BAGT9700-SeriesSlide the data cable Data Cables Blue BAGModels T9300, T9500HRT, T9600HRT & T9600HRT Comfort Auto CalibrationClockwise 1/4-turn at a Time Belt Tension