Cisco MDS 9100 Series Hardware Installation Guide
OL-16187-01
Chapter2 Installing the Cisco MDS 9100 Series
Removing and Installing Components
Removing and Installing Components
The Cisco MDS 9140 Switch and the Cisco MDS 9120 Switch is shipped with two field-replaceable
power supplies. Each power supply includes a fixed fan. The CiscoMDS 9140 Switch and the
Cisco MDS 9120 Switch also have two field-replaceable fan modules. The Cisco MDS 9134 Switch has
two hot-swappable power supplies and two hot-swappable fan modules. The CiscoMDS 9124 Switch is
shipped with one field-replaceable power supply and three fixed fans.
This section provides the following information:
Removing and Installing Power Supplies, page 2-29
Removing and Installing Fan Modules, page 2-30
Warning
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution
when servicing.
Statement 1034
Caution During this procedure, wear grounding wrist straps to avoid ESD damage to the switch.
Note The Cisco MDS 9100 Series is only supported for operation with both power supplies and both fan
modules installed, with all fans working.
With two power supplies installed, if one power supply fails, the system can continue to function
normally on a single healthy power supply. However, the failed power supply should be replaced as soon
as possible to provide redundancy.
The fan modules are required to ensure proper cooling of the switches. SeeFigure2-20, Figure 2-21, and
Figure 2-22.