Chapter 1 Product Overview

Switch LEDs

Table 1-2describes the front panel LEDs for the Cisco MDS 9100 Series.

Table 1-2

Switching Module LEDs

 

 

 

LED

Status

Description

 

 

 

Switch status

Green

All diagnostics pass. The module is operational (normal

 

 

initialization sequence).

 

 

 

 

Orange

The module is booting or running diagnostics (normal

 

 

initialization sequence).

 

 

Switch temperature is high. (A minor threshold was exceeded

 

 

during environmental monitoring.)

 

 

 

 

Red

The diagnostic test failed. The module is not operational

 

 

because a fault occurred during the initialization sequence.

 

 

Switch overheated. (A major threshold was exceeded during

 

 

environmental monitoring.)

 

 

 

Power supply

Green

Both power supplies are working.

status

 

 

Orange

One power supply has failed or has been removed.

 

 

 

 

 

Red or all LEDs off

Both power supplies have failed.

 

 

 

Fan module

Green

Both fan modules are working properly.

status

 

 

Orange

One of the fan modules has failed.

 

 

 

 

 

Red

Both fan modules have failed.

 

 

 

Management

Intermittent

Traffic is on the management port.

port link

flashing green

 

 

 

 

Management

Green

Management port is active.

port activity

 

 

Red

Management port is not active.

 

 

 

 

Port speed

On

2-Gbps mode.

 

 

 

 

Off

1-Gbps mode.

 

 

 

Port link

Solid green

Link is up.

 

 

 

 

Steady flashing

Link is up (beacon used to identify port).1

 

green

 

 

 

 

 

Intermittent

Link is up (traffic on port).

 

flashing green

 

 

 

 

 

Solid orange

Link is disabled by software.

 

 

 

 

Flashing orange

A fault condition exists.

 

 

 

1.The flashing green light turns on automatically when an external loopback is detected that causes the interfaces to be isolated. The flashing green light overrides the beacon mode configuration. The state of the LED is restored to reflect the beacon mode configuration after the external loopback is removed.

 

Cisco MDS 9100 Series Hardware Installation Guide

1-12

OL-16187-01

Page 26
Image 26
Cisco Systems MDS 9100 Series manual Led, Status Description