Tyco 5 manual Start-up, Maintenance and storage, Replacing the breathing hose, Replacing the visor

Page 5

4

3. Start-up

See Instructions for Use of the blower device to be used and of the filters. Only use Pro2000 filters.

oCheck intactness of helmet and breathing hose. o Check intactness of visor+face seal.

Fix the breathing hose of the helmet tightly to the blower device.

Screw the filters tightly to the blower device.

Don the blower unit according to its instructions.

Switch on the blower device, then check adequate air flow (see Instructions for Use of the blower unit).

Loosen the headband using the ratchet knob (handwheel), and don the helmet.

Slip the face seal under the chin.

Tighten the ratchet knob so that the head harness fits comfortably over the forehead. It may be necessary to adjust the crown strap to position the visor to the correct height.

Pull te facepiece back so that it fits comfortably and securely under the chin and around the cheeks. The face seal shall fit above the ears and under the head harness.

The breathing hose trails freely down the back and is not kinked or looped.

4. Maintenance and storage

Store in a cool and dry place (-10 °C...+30 °C, max. 75 % RH), protected from sunlight and any impurities.

Clean with a damp cloth or sponge (be careful not to scratch the visor). Use lukewarm water and mild detergent (neutral, pH 6-8) (e.g. washing-up liquid). Allow to dry. Do not use solvents (e.g. acetone, turpentine) or bleaching agents (perborate, percarbonate). Never clean with compressed air or compressed water.

Check intactness of visor, helmet and hose, and replace damaged items.

Recommend replacement after 2 years if in every day use, particularly when used outdoors. Service life of 5 years when properly stored.

Only use original spare parts.

Replacing the breathing hose

Unscrew the old hose from the airduct and screw in the new one.

Replacing the visor

Release the elastic loops from the head harness. Tilt the visor fully up until the visor is released from pivot arm. Pull the exhalation valve from the face seal and fit it to the new visor’s face seal.

Check that the face seal is fully located arount the valve body. Locate the visor in the pivot arms in a tilted-up attitude, then tilt down to clip into place.

Image 5
Contents Flowhood English Spare parts AccessoriesMarkings SymbolsLimitations of use 064286General Start-up Maintenance and storageReplacing the breathing hose Replacing the visorReplacing the pivot arms Replacing the exhalation valveReplacing the brim trim Replacing the head harnessErsatzteile Zusatzausstattung DeutschMarkierungen SymboleEinschränkungen AllgemeinesWartung und Lagerung InbetriebnahmeAustausch des Atemschlauchs Austausch der SichtscheibeAustausch des Hebelarms Austausch des AusatemventilsAustausch des Helmrahmens Austausch der KopfbänderungPièces de rechange AccessoiresMarquage SymbolesLimites d’utilisation GénéralitésRemplacement du tuyau respiratoire Mise en serviceRemplacement de la visière Entretien et entreposageRemplacement des pivot-bras Remplacement de la soupape expiratoireRemplacement de la bordure Remplacement du harnais