Inter-Tel PATL41106.0 user manual HOW to USE a Preset Program, Select one of the preset programs

Page 14

HOW TO USE A PRESET PROGRAM

1 Insert the key into the console.

See HOW TO TURN ON THE POWER on page 12.

2 Select one of the preset programs.

To select a preset program, press one of the twelve preset program buttons; “P1,” “P2,” “P3,” “P4,” “P5,” “P6,” “P7,” “P8,” “P9,” “P10,” “P11,” or “P12” will appear in the priority display for a few seconds.

A few seconds after a preset program is selected, the maximum incline setting of the program and the maximum speed setting of the program will flash in the display for a few seconds. The display will also show how long the program will last. In addition, a profile of the speed settings of the pro- gram will scroll across the matrix.

Press the Start button or the Speed increase

3 button to start the program.

A moment after you press the button, the treadmill will automatically adjust to the first speed and in- cline settings of the program. Hold the handrails and begin walking.

Each program is divided into 30 one-minute seg- ments. One speed setting and one incline setting are programmed for each segment. Note: The same speed setting and/or incline setting may be programmed for two or more consecutive seg- ments.

settings for the next several segments will be shown in the columns to the right.

When only three seconds remain in the first seg- ment of the program, both the Current Segment column and the column to the right will flash and a series of tones will sound. If the speed and/or in- cline of the treadmill is about to change, the speed setting and/or the incline setting will flash in the display to alert you.

When the first segment is completed, all speed settings will move one column to the left. The speed setting for the second segment will then be shown in the flashing Current Segment column, and the treadmill will automatically adjust to the speed and incline settings for the second seg- ment. Note: If all seven of the indicators in the Current Segment column are lit, the speed settings may move downward so that only the highest indi- cators appear in the matrix.

The program will continue in this way until the speed setting for the last segment is shown in the Current Segment column and the last segment ends. The walking belt will then slow to a stop.

If the speed or incline setting for the current seg- ment is too high or too low, you can manually override the setting by pressing the Speed or Incline buttons. Every few times a Speed button is pressed, an additional indicator will appear or dis- appear in the Current Segment column; if any of the columns to the right of the Current Segment column have the same number of lit indicators as the Current Segment column, an additional indica- tor may appear or disappear in those columns as well. Important: When the current segment of the program ends, the treadmill will automati- cally adjust to the speed and incline settings for the next segment.

To stop the program at any time, press the Stop button. To restart the program, press the Start but- ton or the Speed increase button. The walking belt will begin to move at 2 Km/h. When the next seg- ment of the program begins, the treadmill will auto- matically adjust to the speed and incline settings

The speed setting for the first segment will be shown in the flash- ing Current Segment column of the matrix. (The incline settings are not shown in the matrix.) The speed

Current Segment

for the next segment.

14

Image 14
Contents Model No. PATL41106.0 Serial No Please Contact OUR CUS- Tomer Service Department DirectlyQUESTIONS? Table of Contents Important Precautions Page Before YOU Begin Back Right SideAssembly Make sure that the power cord is unpluggedPage Page Chest Pulse Sensor Care and Maintenance HOW to USE the Chest Pulse SensorHOW to PUT on the Chest Pulse Sensor Chest Pulse Sensor TroubleshootingPRE-LUBRICATED Walking Belt Operation and AdjustmentHOW to Plug in the Power Cord Features of the Console HOW to Turn on the Power HOW to USE the Manual ModeMeasure your heart rate if desired Turn on the fan if desiredHOW to USE a Preset Program Select one of the preset programsFollow your progress with the matrix Display HOW to USE a Pulse Program Follow your progress with the matrix Display HOW to Connect Your Portable Stereo HOW to Connect the Treadmill to USE Ifit ProgramsHOW to Connect Your MP3 Player or CD Player Audio CableHOW to Connect Your Home Stereo HOW to Connect Your ComputerSelect the iFIT mode HOW to Connect Your VCRHOW to USE AN Ifit MP3, CD, or Video Program Press the Play button on your MP3 player, CD Player, or VCRMeasure your heart rate if desired Return to the treadmill and stand on the foot HOW to USE AN Ifit Program Directly from OUR WEB SiteFollow the on-line instructions to start Program Information Mode Important If aHOW to Move the Treadmill HOW to Fold and Move the TreadmillHOW to Fold the Treadmill for Storage HOW to Lower the Treadmill for USE Troubleshooting Problem The power turns off during useProblem The walking belt slows when walked on Top Problem The chest pulse sensor does not function properly Workout Guidelines Conditioning GuidelinesExercise Intensity Exercise FrequencySuggested Stretches R0906A Key Qty DescriptionExploded Drawing a Exploded Drawing B-Model No. PATL41106.0 R0906A Exploded Drawing C-Model No. PATL41106.0 R0906A Exploded Drawing D-Model No. PATL41106.0 R0906A Goodfamily, Inc Ordering Replacement PartsLimited Warranty

PATL41106.0 specifications

The Inter-Tel PATL41106.0 is a versatile and robust communication device that serves as an essential component in modern telephony systems. Part of Inter-Tel’s family of telecommunications solutions, this device is designed to enhance both functionality and user experience in business environments.

One of the main features of the PATL41106.0 is its compatibility with advanced VoIP (Voice over Internet Protocol) technologies. This allows users to make voice calls over the internet, which significantly reduces communication costs, particularly for long-distance calls. Its support for SIP (Session Initiation Protocol) enables seamless integration with various IP-based communications systems, providing businesses with flexibility in their communications infrastructure.

The device is equipped with multiple lines, allowing users to handle several calls simultaneously. This is particularly advantageous for busy office environments where efficient call management is crucial. The PATL41106.0 also includes programmable keys that can be customized for quick access to frequently dialed numbers or specific features, improving workflow and productivity.

Another characteristic of the Inter-Tel PATL41106.0 is its user-friendly interface. The device features an intuitive display that provides essential information such as caller ID, call status, and menu navigation options. This ensures that users can easily access and manage their calls without getting bogged down by complicated procedures.

Moreover, the PATL41106.0 supports a variety of audio codecs, enhancing call quality even in environments with limited bandwidth. This adaptability makes it a reliable choice for businesses that require consistent communication regardless of their internet conditions.

In terms of installation and maintenance, the device is designed for straightforward integration with existing telecommunications systems. Its compact design and robust build ensure longevity and ease of placement in various office settings.

Finally, the Inter-Tel PATL41106.0 is equipped with advanced security features to protect against unauthorized access and to ensure the integrity of communications. This focus on security is crucial in today’s business landscape, where data protection is of utmost importance.

Overall, the Inter-Tel PATL41106.0 offers a compelling suite of features and technologies, making it a practical choice for businesses looking to enhance their telecommunications capabilities. With its blend of functionality, adaptability, and user-friendly design, this device is an integral part of any modern communication strategy.