Spirit IN300T, IN400T Incline Feature, Dot Matrix Center Display Manual Operation, Mile Track

Page 9

Incline Feature:

May be adjusted anytime after belt movement.

Press and maintain Adjust ▲▼ keys (console or hand rail) to achieve desired level of effort. You may also choose a more rapid increase / decrease by selecting desired value on left hand (incline).

Display will indicate incline percent as adjustments are made.

Incline will remain in it’s position when display is turned off.

Dot Matrix Center Display (Manual Operation):

Twenty rows of “dots”(8 high) indicate each segment of a workout. The dots are only to show an approximate level (speed/incline) of effort. They do not necessarily indicate a specific value - only an approximate percent to compare levels of intensity.

In Manual Operation the Speed / Incline dot matrix window will build a profile “picture” as values are changed during a workout. The dot matrix window will show the speed profile when mph is adjusted. A small flashing light (near Speed window) indicates the dot matrix value is speed. If incline is adjusted (small light is steady), the dot matrix window will become an incline profile. Only a slight press of the appropriate key is required to change the dot matrix display from speed to incline (visa-versa). This window will remain a speed or incline profile based on last adjustment. Only the vertical segment that flashes will be changed (along with all to the right). This display profile picture is based on a 20 minute workout. After 20 minutes the dot will adjust “backwards” (to the left).

1/4 Mile Track*:

The 1/4 mile track will be displayed around the dot matrix window. The flashing dot indi- cates your progress. Once the 1/4 mile is complete this feature will begin again.

*Manual operation only

Reset Feature*:

While in Pause mode, press and maintain the ENTER reset key until the clock, Distance and Calorie values zero out. You may restart your workout with different values or reset clock (countdown).

*Manual operation only

Pulse Grip Feature:

The Pulse (Heart Rate) console window will display your current heart rate in beats per minute during the workout. You must use both stainless steel sensors on the front cross bar to display your pulse. Pulse value displays anytime the upper display is receiving a Grip Pulse signal. You may not use the Grip Pulse feature while in Heart Rate Control.

Note: Refer to Important Safety Instructions (page 2) concerning Pulse Grip operation.

Calorie Display:

Displays the cumulative calories burned at any given time during your workout.

Note: This is only a rough guide used for comparison of different exercise sessions, which

cannot be used for medical purposes. Calories are not calculated while in Heart Rate

Control.

To Turn Treadmill Off (Blank out Display):

Two methods accomplish this: Use either one.

(1)Display will automatically turn off (blank out) after 4 minutes (no key operations) in Pause / Stop mode. Display will “wake” back up in mode it was in when it auto- matically blanked out.

(2)Remove tether cord. This clears the display to “wake” back up in Manual mode.

7

Image 9
Contents IN300T IN400T Table of Contents Product Registration Important Safety Instructions Grounding Instructions Important Electrical InformationImportant Operation Instructions Safety Tether CordTransport IN300T / 400T Folding InstructionsTo Fold The Treadmill To Unfold The TreadmillOperation of Your Treadmill Reset Feature Incline FeaturePulse Grip Feature Dot Matrix Center Display Manual OperationProgrammable Operation of Your Treadmill Programmable FeaturesTo Select a Program Dot Matrix DisplayTarget Heart Rate Training ChartErratic Operation Using a Heart Rate TransmitterSpecial Operations of Heart Rate Functions Heart Rate ControlHow the Heart Rate Control Program Works Selecting a Heart Rate Control Program H-1 to H-3Heart Rate Monitor Only Heart Rate Control OperationBelt Adjustments General MaintenanceTreadbelt Tracking Adjustment Problem SOLUTION/CAUSE Service Checklist Diagnosis GuideTreadmill Warranty Manufacturer’s Limited Warranty

IN300T, IN400T specifications

The Spirit IN400T and IN300T are two advanced technology ventilators designed to meet the essential requirements of critical care ventilation. These devices, primarily used in hospitals or emergency settings, offer a combination of innovative features and robust performance tailored to provide optimal respiratory support.

The Spirit IN400T stands out with its intelligent dual-mode operation. It seamlessly switches between invasive and non-invasive modes, allowing healthcare professionals to adapt the settings based on patient needs. This flexibility ensures that patients experiencing respiratory distress or requiring postoperative support receive appropriate ventilation, improving overall outcomes. The IN400T is equipped with a user-friendly interface, providing intuitive navigation through a straightforward menu. Its large color display presents real-time data, making it easy for clinicians to monitor patient parameters at a glance.

In contrast, the Spirit IN300T focuses on delivering reliable performance in a compact design. It features advanced pressure and volume control modes, catering to a wide range of patient needs, from neonates to adults. The IN300T’s unique Waveform Monitoring feature enables clinicians to analyze respiratory mechanics effectively, helping them make informed decisions regarding patient care. Additionally, this model incorporates Smart Adaptive Technology, which automatically adjusts ventilation settings in response to the patient's requirements, enhancing safety and comfort.

Both models incorporate high-efficiency filters and comply with stringent infection control protocols. Their sleek designs make them easy to transport, ensuring they can be utilized in various settings, including intensive care units, emergency departments, and during patient transfers. The battery backup system in both devices provides uninterrupted operation during power outages, a crucial feature for critical care applications.

Moreover, the Spirit IN400T and IN300T are equipped with advanced alarm systems that notify healthcare teams of any deviations from preset parameters, helping to ensure timely intervention and reduce risks. The devices are also compatible with various accessories and monitoring systems, allowing for enhanced functionality and adaptability.

In summary, the Spirit IN400T and IN300T ventilators represent the forefront of respiratory support technology. Their key features, such as dual-mode operation, intelligent adaptive technology, and comprehensive monitoring capabilities, make them invaluable tools in managing patients with complex respiratory needs, ultimately contributing to improved patient care and outcomes in critical settings.