Chauvet 152B Setting up a DMX Serial Data Link, Able Connectors, PIN to 5 PIN Conversion CH ART

Page 9

C ABLE CONNECTORS

Cabling must have a male XLR connector on one end and a female XLR connector on the other end.

DMX connector configuration

 

 

COMMON

 

1

DMX +

INPUT

3

 

 

2

DMX -

 

 

1

Resistance 120

ohm ¼ W between

3

pin 2

(DMX -) and

2

pin 3

(DMX +) of

the last fixture.

1

OUTPUT

3

2

Termination reduces signal errors. To

avoid signal transmission problems

 

 

and interference, it is always

 

advisable to connect a DMX signal

 

terminator.

CAUTION Do not allow contact between the common and the fixture’s chassis ground. Grounding the common can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other.

3- PIN TO 5 - PIN CONVERSION CH ART

Note! If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter. The chart below details a proper cable conversion:

3PIN TO 5 PIN CONVERSION CHART

Conductor

3 Pin Female (output)

5 Pin Male (Input)

 

 

 

Ground/Shield

Pin 1

Pin 1

 

 

 

Data ( - ) signal

Pin 2

Pin 2

Data ( + ) signal

Pin 3

Pin 3

Not Used

 

Pin 4

Not Used

 

Pin 5

Setting up a DMX Serial Data Link

Universal DMX Controller

1.Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the controller.

2.Connect the end of the cable coming from the controller which will have a (female) 3 pin connector to the input connector of the next fixture consisting of a (male) 3 pin connector.

3.Then, proceed to connect from the output as stated above to the input of the following fixture and so on.

This drawing provides a general illustration of the DMX Input/Output panel of a lighting fixture.

Continue the link

LEDsplash™ 152B User Manual

9

3/9/2010 3:02 PM

Image 9
Contents LEDsplash 152B Table of Contents AC Power What is includedBefore YOU Begin Unpacking InstructionsSafety Instructions Features IntroductionDMX Channel Summary Product Overview Product Dimensions Fuse Replacement SetupFixture Linking Data CablingSetting up a DMX Serial Data Link Able ConnectorsPIN to 5 PIN Conversion CH ART Mounting Master/Slave Fixture LinkingI E N T AT IO N RiggingMaster/Slave Mode Master Sound, Master Auto Operation Stand-Alone Mode Sound-Active, Auto ModeDipswitch Functions Operating InstructionsDMX Channel Values DMX ModeOFF Setting the DMX ST Arting AddressDMX Quick Reference CH ART DMX Address Quick Reference ChartApplies to General TroubleshootingAppendix General MaintenanceTechnical Support DMX PrimerClaims Returns ProcedurePower Technical Specifications