Fostex X-12 Try speaking into the mic, For optimum gain, adjust the LINE-MIC knob CW toward MIC

Page 10

Model X-12 Owner's Manual

6When the leader part is forwarded, press the [RESET] button to set the counter to

"000."

7Select the track to be recorded with the [REC TRACK] selector.

Select track 1 (the indicator will change to red) or whatever track you prefer to record on.

This will change to red light and track 1 can be recorded.

1

<NOTE>

Do not move the [REC TRACK] selector during recording. If this is moved accidentally during recording, the recording track will switch.

8Try speaking into the mic.

The level meter LED will blink.

9For optimum gain, adjust the [LINE-MIC] knob CW (toward "MIC").

Adjust the [LINE-MIC]knob such that the level meter "+3" LED is illuminated at maximum sound volume.

When recording line level sound sources such as a keyboard and electric guitar, the optimum gain is obtained by rotating the

[LINE-MIC]knob CCW (toward "LINE").

10Put X-12 in the record standby mode.

First, press the [PAUSE] button, then the [RECORD] button. The [PLAY] button will be engaged automatically at the same time.

The tape will remain paused in the record mode.

11When the [LINE OUT/PHONES] knob is slowly advanced, the input monitor sound

will be heard in the headphone.

While monitoring the sound in the headphone, watch the level meter and adjust the recording to a suitable level.

Because the recording level cannot be adjusted with a fader, optimum recording levels must be determined by the sound volume applied to the mic or by adjusting the distance to the mic.

<CAUTION>

If you must monitor for a long time, be careful not to raise the [LINE OUT/PHONES] knob too high. If you monitor for long hours at high volumes, it could impair your hearing.

12 After confirming the level, release the [PAUSE] button (The [PAUSE] button is pressed again) to start recording.

13 If recording is to be momentarily stopped,

press the [PAUSE] button. If recording is to

be ended, press the [STOP] button.

Following the procedures up to this point,

the sound applied to the microphone has

METER

+6+6

+3 +3

0 0

If this LED blinks frequently, it indicates that input level is too high.

Set the gain so that LED's within this range remain lit.

been recorded on track 1 as shown in

schematic below.

Now, let's try recording another sound source

to another track with the same procedures.

Also, lets playback the recorded sound on

each track as described below.

-5 -5

-10 -10

<NOTE>

Be careful not to continue recording, if the level meter "+6" LED lights up frequently, as this will indicate the sound can be distorted.

Track 4

Track 3

Track 2

Track 1

Microphone

10

Image 10
Contents Model Safety Instructions Table of Contents Using write-protection tabs Before UsingCassette tape suitable for recording Important Lets not use it this way Names and Functions Record track select indicator AC adaptor connector DC Record track selector REC TrackPower switch Power Counter / Reset button ResetPlayback level fader 1 Record indicator RECPower indicator Power Playback Panpot knob PANAC outlet Basic Operation recordingPress the Play button to forward the tape for a few seconds Put X-12 in the record standby mode For optimum gain, adjust the LINE-MIC knob CW toward MICTry speaking into the mic Basic Operation playback You can play back the recorded TrackAdvanced Operation OverdubbingX-12 will enter record pause mode Using the Playback PAN knob Up to the playback start point reset the counter to MixdownUsing a tape recorded on a boom box or cassette deck Troubleshooting MaintenanceSpecifications Block DiagramAccessories option SpecificationsFostex Distributors List in Europe