6. Error Displays

Error Display

Cause

Correction

 

 

 

 

Your palms or soles are not in firm contact

Press your palms or soles firmly to the

 

electrodes, then measure. (Refer to Section

 

with the electrodes.

 

4.)

 

 

 

 

 

 

The posture for measurement is wrong or

Measure without moving the hands or soles.

 

the palms or soles are not in firm contact

 

(Refer to Section 4.)

 

with the electrodes.

 

 

 

 

 

 

The palms or soles are too dry.

Moisten the palms or soles with a wet towel,

 

then repeat measurement.

 

 

 

 

 

 

 

• Please ensure that age, gender and height

 

 

settings stored as personal data are

 

Values of body composition are out of

correct (see Setting Items in Section 9).

 

• The main unit cannot measure body

 

measurable range.

 

composition outside its measurement

 

 

 

 

range, even if the Age, Gender and Height

 

 

settings are correct.

 

 

 

 

 

Insert the batteries again and repeat

 

Abnormal operation.

measurement.

 

If this error still occurs, consult your

 

 

 

 

OMRON service representative.

 

 

 

 

You stepped on the unit before the display

Step on the main unit after the display

 

indicated “0.0 kg”.

indicates “0.0 kg”.

 

 

 

 

You moved the main unit before the display

Do not move the main unit until the display

 

indicated “0.0 kg”.

indicates “0.0 kg”.

 

 

 

 

You moved your body while measuring body

Do not move while measuring body weight.

 

weight.

 

 

 

Body weight of 150 kg (330.0 lb) or over is

 

Your weight is 150 kg (330.0 lb) or over.

out of the measuring range of this unit. You

 

 

cannot use this unit.

 

 

 

7. Troubleshooting

Problem

Cause

Correction

 

 

 

The displayed value of body

 

 

composition is abnormally high or

Refer to “Useful Information”.

 

low.

 

 

 

 

 

The power turns off approximately 5

You did not select the correct

 

minutes after the body weight is

personal profile number or the

Select the correct personal profile

confirmed and before your body fat

GUEST mode. (The personal profile

number or the GUEST mode. (Refer

percentage, visceral fat level and

number or “G” is not displayed on

to Section 4.)

skeletal muscle percentage is

the display unit.)

 

measured.

 

 

 

 

 

 

 

Batteries are not inserted.

Insert the batteries.

 

 

 

 

The polarities of batteries are not

Insert the batteries in correct

 

aligned correctly.

alignment.

Nothing is displayed when the

 

 

The batteries are worn out.

Replace all four batteries with new

power is turned on.

ones. (Refer to Section 2.)

 

 

 

 

 

The cord connecting the main unit

Contact the nearest OMRON

 

and the display unit is damaged or

 

service representative.

 

worn.

 

 

 

 

 

EN

11

Image 12
Contents Body Composition Monitor Contents Body Composition MonitorUseful Information Body fat has low electric conductivityRecommended measurement times Avoid taking measurements under the following conditionsVisceral fat = fat surrounding internal organs Subcutaneous fat = fat below the skinOpen the battery cover on the back of the main unit Battery Life and ReplacementKnow Your Unit Inserting and Replacing the BatteriesSetting and Storing Personal Data Turn on the powerSelecting Measurement Unit Press the SET/MODE button to confirmTurn on the Power Delete the personal data Power SwitchChanging the Personal Data Deleting the Personal DataTurn on the power Start measurement When the 0.0 kg is displayed, take out the display unitTaking a Measurement Select the personal profile numberCorrect Posture for Measurement Postures to Avoid During MeasurementInterpreting the Body Fat Percentage Result Check the measurement resultsMeasuring Weight Only Error Displays TroubleshootingHow to Take Care of and Store the Unit How to Clean the UnitCare and Storage Technical Data BMITechnical Data 24, Yamanouchi Yamanoshita-cho, Ukyo-ku, Kyoto Japan Kruisweg 577, 2132 NA Hoofddorp, The NetherlandsJohn-Deere-Str a, 68163 Mannheim, Germany 14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, France