Newcon Optik LRM 220SI operation manual Compass calibration, Gating mode

Page 20

Magnetic North (not True North). If the unit detects large installation errors (unit is not well levelled or not aimed to the North), then LCD will show result “444” and “99”, which means that correction was not performed due to incorrect setup.

Compass calibration

If the System was exposed to a strong magnetic field or was not in use for a long time, the compass accuracy may diminish.

To return the compass into working condition:

Select CALc from CAL menu

Keeping the unit horizontal, perform one full rotation around vertical axis within half a minute and then one full rotation around vertical axis with device upside down during half

a minute.

If one rotation does not restore calibration – perform two rotations.

Normal compass function should now be restored.

Gating mode

In this mode gating function is activated. Here the minimal distance to the target can be set. Any object closer than the gating distance will be ignored.

To select Gating Mode:

Select GAtE from the mode menu

16

Image 20
Contents Laser Range Finder Monocular Page Important Information Read prior to activationPage Table of Contents Brief Description Principle of operationKey Features Device Appearance Front viewPage Delivery SET Standard delivery setCompass SpecificationsRange Finder Laser Measuring range Accuracy Power InclinometerSpeed Detector EnvironmentalOperation Instructions Changing battery To install a battery To remove batteryMeasuring procedure Maximum distanceTarget selection logic Operation and service modes Accuracy correction Std Gating mode Compass calibrationIndividual Measurement and Scanning regimes Data Recall mode Additional display information Or MBest Measuring Technique Storage and Maintenance Troubleshooting Compass shows zero at any directionWarranty What This Warranty Does Not CoverCustomer Support Quality Certificate Page Page Newcon Optik