5. SYMPTOM: THE WALKING BELT IS OFF-CENTER WHEN WALKED ON

a. If the walking belt has shifted to the left, first remove the key and UNPLUG THE POWER CORD. Using the 3/16” end of the allen wrench, turn the left rear roller adjustment bolt clockwise, and the right bolt counterclockwise, 1/4 of a turn each. Be careful not to overtighten the walking belt. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is centered.

b. If the walking belt has shifted to the right, first remove the key and UNPLUG THE POWER CORD. Using the 3/16” end of the allen wrench, turn the left rear roller adjustment bolt counter- clockwise, and the right bolt clockwise, 1/4 of a turn each. Be careful not to overtighten the walking belt. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is centered.

c. If the walking belt slips when walked on, first remove the key and UNPLUG THE POWER CORD. Using the 3/16” end of the allen wrench, turn both rear roller adjustment bolts clockwise, 1/4 of a turn. When the walking belt is correctly tightened, you should be able to lift each side of the walking belt 2-3 inches off the walking platform. The center of the walking belt should just touch the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is prop- erly tightened.

a

b

c

6. SYMPTOM: ONE OF THE UPPER BODY ARMS SQUEAKS DURING USE

a. Correcting this problem requires a small amount of white marine grease, available at most hardware stores.

Turn the Resistance Knob (97) counterclockwise until it can be removed. Remove the Resistance Cone (98) and the Upper Body Arm (96), along with the 3/8” Washers (67), Spring Washer (5), Thrust Washers (101), and Thrust Bearing (102). (Note: If the Resistance Sleeve [99] comes out of the Resistance Bracket [104], press it back in.) Apply a thin layer of white marine grease to the outer surface of the Resistance Cone (98). Reattach all parts in the order shown at the right.

104

96

 

99

 

98

 

 

 

101

 

 

5

97

 

67

 

 

102

 

 

67

 

7.SYMPTOM: THE DISPLAYS OF THE CONSOLE DO NOT FUNCTION PROPERLY

a.Check the batteries in the console. (See BATTERY INSTALLATION on page 8.) Most problems are the re- sult of drained batteries.

b.If the speed display does not show a correct reading, remove the key and UNPLUG THE POWER CORD. Raise the treadmill to

the storage position. (See HOW TO FOLD THE TREADMILL FOR STORAGE on page 10.) Remove the four indicated screws. Next, lower the treadmill. (See HOW TO LOWER THE TREAD- MILL FOR USE on page 11). Remove the four screws from the sides of the hood. Carefully slide the hood forward and remove it. See page 14 for further instructions.

Screws

13

Image 13
Contents SEARS, Roebuck and CO., Hoffman ESTATES, IL Model No Serial NoImportant Precautions Table of ContentsPage Front Before YOU BeginBack Right SidePhillips screwdriver , and two adjustable wrenches AssemblyTighten the Handrail Bolt yet. Using the allen wrench Restraining TiePage HOW to Plug in the Power Cord Operation and AdjustmentPerformant Lubetm Walking Belt Battery Installation Diagram of the ConsoleStep by Step Console Operation Reset the speed control Insert the key fully into the power switchCALORIES/FAT CAL Measure your pulse, if desiredHOW to Change the Incline of the Treadmill HOW to Fold and Move the TreadmillHOW to USE the Upper Body Arms HOW to Fold the Treadmill for StorageHOW to Lower the Treadmill for USE HOW to Move the TreadmillSymptom the Power does not Turn on TROUBLE-SHOOTINGSymptom the Power Turns OFF During USE Symptom the Walking Belt Slows When Walked onSymptom ONE of the Upper Body Arms Squeaks During USE Symptom the Walking Belt is OFF-CENTER When Walked onTop Conditioning GuidelinesExercise Intensity Fat BurningWorkout Guidelines HOW to Measure Your Heart RateSuggested Stretches Hardware Identification Chart Key No. Part No. Qty Description Part LIST-Model NoExploded DRAWING-Model No .297381 R0497A Model No Full 90 DAY WarrantySEARS, Roebuck and CO., Dept WA, Hoffman ESTATES, IL