ProForm PETL41106.0 user manual Troubleshooting, Problem The power turns off during use

Page 26

TROUBLESHOOTING

Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, please see the front cover of this manual.

PROBLEM: The power does not turn on

SOLUTION: a. Make sure that the power cord is plugged into a properly earthed outlet (see page 10). If an exten- sion cord is needed, use only a 3-conductor, 1 mm2 (14-gauge) cord that is no longer than 1.5 m (5 ft.). Important: The treadmill is not compatible with GFCI-equipped outlets.

b. After the power cord has been plugged in, make sure that the key is inserted into the console.

c.Check the circuit breaker located on the treadmill near the power cord. If the switch protrudes as shown, the circuit breaker has tripped. To reset the circuit breaker, wait for five minutes and then press the switch back in.

d.Check the on/off switch located on the treadmill near the power cord. The switch must be in the “on” position.

PROBLEM: The power turns off during use

c

 

Tripped

Reset

d

On

 

 

Position

SOLUTION: a. Check the circuit breaker located on the treadmill frame near the power cord (see the drawing above). If the circuit breaker has tripped, wait for five minutes and then press the switch back in.

b.Make sure that the power cord is plugged in. If the power cord is plugged in, unplug it, wait for five minutes, and then plug it back in.

c.Remove the key from the console. Reinsert the key into the console.

d.Make sure that the on/off switch is in the “on” position (see d. above).

e.If the treadmill still will not run, please see the front cover of this manual.

PROBLEM: The incline of the treadmill does not change correctly

SOLUTION: a. With the key in the console, press one of the Incline buttons. While the incline is changing, re- move the key. After a few seconds, re-insert the key. The treadmill will automatically rise to the maximum incline level and then return to the minimum level. This will recalibrate the incline system.

PROBLEM: The display of the console does not function properly

SOLUTION: a. Remove the key from the console and UNPLUG THE POWER CORD. With the help of a second person, carefully tip the Uprights (84) down as shown. Next, remove the three Screws (83) and the three hood Screws (3). Note: A phillips screwdriver with a shaft at least 13 cm (5 in.) long is required.

a

3

83

 

84

 

 

 

3

26

Image 26 Contents
QUESTIONS? Model No. PETL41106.0 Serial NoTable of Contents Important Precautions Page Before YOU Begin Back Right SideAssembly Make sure that the power cord is unpluggedPage Page Chest Pulse Sensor Care and Maintenance HOW to USE the Chest Pulse SensorHOW to PUT on the Chest Pulse Sensor Chest Pulse Sensor TroubleshootingPRE-LUBRICATED Walking Belt Operation and AdjustmentHOW to Plug in the Power Cord GFCI-equipped outletsFeatures of the Console HOW to Turn on the Power HOW to USE the Manual ModeMeasure your heart rate if desired Turn on the fan if desiredHOW to USE a Preset Program Select one of the preset programsFollow your progress with the matrix Display HOW to USE a Pulse Program Follow your progress with the matrix Display HOW to Connect Your Portable Stereo HOW to Connect the Treadmill to USE Ifit ProgramsHOW to Connect Your MP3 Player or CD Player Audio CableHOW to Connect Your Home Stereo HOW to Connect Your ComputerSelect the iFIT mode HOW to Connect Your VCRHOW to USE AN Ifit MP3, CD, or Video Program Press the Play button on your MP3 player, CD Player, or VCRMeasure your heart rate if desired Return to the treadmill and stand on the foot HOW to USE AN Ifit Program Directly from OUR WEB SiteFollow the on-line instructions to start Program Information Mode Important If aHOW to Move the Treadmill HOW to Fold and Move the TreadmillHOW to Fold the Treadmill for Storage HOW to Lower the Treadmill for USE Troubleshooting Problem The power turns off during useProblem The walking belt slows when walked on Top Problem The chest pulse sensor does not function properly Workout Guidelines Conditioning GuidelinesExercise Intensity Exercise FrequencySuggested Stretches R0806A Key Qty DescriptionExploded Drawing a Exploded Drawing B-Model No. PETL41106.0 R0806A Exploded Drawing C-Model No. PETL41106.0 R0806A Exploded Drawing D-Model No. PETL41106.0 R0806A Ordering Replacement Parts