ProForm 590 rt Make sure that the power cord is unplugged, Do not fully fold the Frame yet

Page 7

1. Make sure that the power cord is unplugged.

1

86

60

 

With the help of a second person, carefully tip

 

the treadmill onto its left side. Partially fold the

 

 

88

 

Frame (53) so that the treadmill is more stable;

 

Hole

 

2

do not fully fold the Frame yet.

 

 

Cut the shipping tie securing the Upright Wire

 

 

 

 

(86) to the Base (60). Locate a tie in the indi-

 

 

 

 

cated hole in the Base, and use the tie to pull

 

 

 

 

the Upright Wire out of the hole.

53

89 88 2

 

 

Attach two Base Feet (88) to the Base (60) in the

 

 

locations shown with two #8 x 1" Tek Screws (2)

 

 

 

 

and two Base Foot Spacers (89). Then, attach

 

 

88

 

two Base Feet (88) with two #8 x 1" Tek Screws

 

 

2

(2).

 

 

 

 

 

 

 

8988

2

 

 

 

 

 

2. Attach a Wheel (90) to the Base (60) with a 3/8"

2

 

 

 

 

x 2" Bolt (3) and a 3/8" Locknut (11). Do not

 

 

 

 

overtighten the Locknut; the Wheel must

 

60

 

85

turn freely.

 

 

Press a Base Cap (85) into the Base (60).

 

3

 

 

 

See the inset drawing. Cut the plastic tie near

 

 

 

 

the Upright Wire (86).

 

 

 

 

 

 

 

11

90

 

Cut

 

 

 

 

86

 

 

 

 

 

3. Identify the Right Upright (79) and the Right

3

 

 

 

 

Upright Spacer (83), which are marked with

 

 

 

 

“Right” stickers. Insert the Upright Wire (86)

 

 

 

 

79

through the Right Upright Spacer as shown.

 

 

 

 

Then, set the Right Upright Spacer on the Base

86

Wire Tie

 

 

(60).

 

8683

Have a second person hold the Right Upright

 

 

 

 

(79) near the Base (60). See the inset drawing.

 

 

 

 

 

Tie the wire tie in the Right Upright securely

 

 

 

 

 

around the end of the Upright Wire (86). Then,

 

 

 

 

 

pull the other end of the wire tie until the Upright

 

 

 

 

 

Wire is routed completely through the Right

 

79

 

 

60

Upright.

 

 

 

 

86

Wire

 

 

 

 

 

Tie

 

 

 

7

Image 7
Contents On the WEB QUESTIONS?Model No. PFTL75909.0 Serial No Mon.-Fri a.m.-6 p.m. MT Sat a.m.-4 p.m. MTTable of Contents Pulse sensor is not a medical device Important PrecautionsTreadmill is not in use. See the drawing on Power cord, and switch the reset/off cirTreadmill, and before performing the mainte Cuit breaker to the off position whenBefore YOU Begin Assembly Do not fully fold the Frame yet Make sure that the power cord is unpluggedOvertighten the Locknut the Wheel must Turn freely Page Do not fully tighten the Bolts yet With a second Bolt Spacer 84, 3/8 x 4 Bolt 3/8 Star WasherBolts yet Not fully tighten the Bolts yet105 Console Wire Wire Tie Be careful not to pinch the wires in the Right Handrail Raise the Frame 53 to the position shown HOW to Plug in the Power Cord Operation and AdjustmentPRE-LUBRICATED Walking Belt Features of the Console Console DiagramHOW to USE the Manual Mode HOW to Turn on the PowerMeasure your heart rate if desired Select one of the ten preset workouts. To select an aerobic HOW to USE a Preset WorkoutInformation Mode HOW to USE the Stereo Sound SystemHOW to Move the Treadmill HOW to Fold and Move the TreadmillHOW to Lower the Treadmill for USE Problem The power turns off during use TroubleshootingCompatible with GFCI-equipped outlets Make sure that the gap between the Magnet Reed Switch is about 1/8 in mm. If necProblem The walking belt slows when walked on TopProblem Solution Exercise Frequency Exercise GuidelinesExercise Intensity Workout GuidelinesSuggested Stretches R0909A Part LIST-Model No. PFTL75909.0105 Right Handrail Userʼs Manual 106 Lift Motor Wire Exploded Drawing A-Model No. PFTL75909.0 R0909A Exploded Drawing B-Model No. PFTL75909.0 R0909A Exploded Drawing C-Model No. PFTL75909.0 R0909A Exploded Drawing D-Model No. PFTL75909.0 R0909A Limited Warranty Ordering Replacement PartsIcon Health & Fitness, Inc., 1500 S W., Logan, UT