BATTERY INSTALLATION

1.Remove the screw on the battery cover located on the back of the main unit.

Use the supplied screwdriver or use

a commercially available small screwdriver to remove the screw on the battery cover.

2.

3.

Open the battery cover.

Insert the battery.

Place the positive (+) side of the battery (CR2032) upward. Insert the battery in the direction of the arrow as illustrated.

4.Replace the battery cover.

Insert the projected portion of the battery cover as illustrated.

Tighten the screw on the battery cover.

NOTES:

The unit will automatically turn off if no button is pressed for 5 minutes.

After installing the battery, set the time of day, weight and stride length.

10

Image 10
Contents Model HJ-720ITC Table of Contents Introduction Important Safety Information Operating the DeviceCare and Maintenance Know Your Unit How to attach the strap to the main unit ComponentsAerobic Step Function 300 x 0.95 = 285 kcalHow to measure your stride length Stride Length MeasurementOpen the battery cover Insert the battery Battery InstallationReplace the battery cover Battery Replacement Press the MEMO/ Button to advance by increments of one hour Setting the TimeSetting range 1200 AM-1159 PM Install the battery Press the SET Button to set the hourPress the SET button to set the minute Press the SET Button to set the weight Setting the WeightSetting range 70 to 300 lb Press the MEMO/ Button To advance by increments of 1 lbPress the MEMO/ Button To advance by increments of 1 inch Setting the Stride LengthSetting range 100 to 400 feet Press the SET Button to set the stride lengthAttaching the Pedometer Place the unit in your pocketUp and down movement Unit moves irregularlyWalking at an inconsistent pace Vibrations from a moving vehicleChanging the Display Using the Event FunctionPress the MODE/EVENT Button to change the display Using the Memory Function Press the MEMO/ Button. The previous day data is displayedUsing the Memory Function Use the System Reset function in the following case Press the System Reset Button on the back of the main unitInstalling the Software Omron Health Management SoftwareOperating Environment Requirements Installing the Software Installing the Software Installing the Software Installing the Software Installing the Software Installing the Software Installing the Software Using the Software Using the Software Open the USB Connector cover Transferring Data to a Personal ComputerTransferring Data to a Personal Computer Software Trouble Shooting Tips Care and Maintenance Clean the unit with a soft dry cloth. Do notTroubleshooting Tips Problem Cause SolutionSpecifications HJ-720ITCFCC Statement Warranty Limited WarrantyPage Omron Healthcare, Inc