Emerson IP221 appendix Appendix I Part Numbers, Options, Sensor Connection, Sensor Type Material

Page 20

Appendix I - Part Numbers

Please note that the existence of a part number does not imply the availability of a unit.

1. Sensors and Sensors with Head Amplifiers

Fitting

Head Amplifier Type

Approval

0

Outside Fitting

P

Sensor Mounted

O

None

2

Double Fitting

U

Adjacent Mounted

H

ATEX

3

Inside Fitting

 

 

L

Lloyds Register of Shipping

6

Inside Fitting M6

 

 

P

PTB

8

Sludge Pipe

 

 

S

SEV

9

Flange

 

 

F

LCIE

 

 

 

 

 

 

Options

 

 

 

 

 

 

T Test Switch

 

 

 

3 0 2 S D P 8 0 T

 

 

 

 

 

 

 

Sensor Connection

Sensor Type

Material

0

PVC Cable & Phono Plugs

 

 

 

 

 

See Catalogue

D

Stainless steel

1

PTFE Cable & Phono Plugs

 

4

PVC Cable & BNC Plugs

 

Y

Epoxy resin

 

5

PTFE Cable & BNC Plugs

 

P

Polyether sulphone

 

7

PVC Cable & Pins

 

J

Cryogenic Epoxy Resin

 

8

PTFE Cable & Pins

 

M

Monel

 

9

Special Cable

 

C

Hastelloy C

 

M

Marine Head Amplifier

 

 

 

 

 

 

 

 

I

Industrial Head Amplifier

 

 

 

 

J

Junction Box

Note: Pre 1984 sensors have an M or an I in the third place to indicate Marine or Industrial head amplifier.

2.Head Amplifiers (Adjacent mounted)

Intrinsic Safety

Mounting

Sensor Type

Test Switch

 

 

 

 

 

3 Intrinsically Safe

A

Standard acting

C

Single

T

Included

 

X

Reverse acting

N

Omitted

 

 

 

M E P 3 A I / 3 C A N

 

Electronics

 

 

Type

3

1 MHz Switched Gain

} Industrial Only

Material

 

I Industrial

4

3.7 MHz Switched

 

A Aluminium Alloy

G Gunmetal

S Stainless Steel

P Plastic

20

Image 20
Contents Contents Safety Information IntroductionInstallation Fault Finding Specification and descriptionProtection of permanently installed equipment Explanation of symbolsHi-Sens cylindrical sensors SensorsGap sensors Interface detection Attenuation method Figure Reflection Method FigureNormal acting head amplifiers Solids Density DetectionHead Amplifier Units Ii Inverse acting head amplifiers Type Industrial Case MarineSensor State Output Control UnitsInstallation 2.1 Calibration Head amplifier internalsIii Interface Sensors Attenuation Method Calibration procedure by sensor type Hi-Sens SensorsIi Gap Sensors Iv Interface Sensors Reflection Method Sludge SensorSensor and head amplifier installation Adjacent head amplifier mounting detailsPage Control unit installation Wiring CableRelay Ratings Ii Head Amplifier UnitIii Control unit Control Unit Connections II 1 G EExia IIC EN 50014 & EN Intrinsically safe installationCertificates of Conformity Fault Finding Fault indicatedUnit not switching Relay contacts not changingSensor specification Head AmplifiersPower consumption Intrinsic safetyTemperature Range HousingRack Mounted Unit Recommended Spare Parts 5.1 Sensor and head amplifierStandard Control Unit Intrinsic Safety Mounting Sensor Type Test Switch Appendix I Part NumbersOptions Sensor ConnectionIntrinsic Safety Mounting Mains Voltage Output Relay RacksAppendix II List of illustrations Section Title Appendix III List of tables Section TitleMaintenance / Inspection Abcdef International Americas