Beginning the Program

During idle mode, the message window displays a message “SELECT A PROGRAM”. To begin this pro- gram, press the CUSTOM TRAINER program key, the LED indicator above it will light up.

Entering the program

When the message display fl ashes, “CUSTOM TRAINER” and “PRESS ENTER”, it indicates you are about to select the Custom Trainer program. Press ENTER Key to enter program setup mode or press the START/STOP key to skip the set up mode and use default values.

Press ENTER key to enter program set up mode. The message display will take you through the pro- gram setup mode step by step as below:

Enter Age

1.The message window will fl ash a message of “ENTER AGE”, then “AGE = XX” with the number blinking.

2.You may press UP or DOWN keys to adjust the age.

3.After age adjustment, the message display will switch to display “PRESS ENTER” to indicate next step. Press ENTER to accept and enter Weight adjustment.

Enter Weight

1.The message window will fl ash a message of “ENTER WEIGHT”, then “WEIGHT = XXX LB” with the number blinking. (WEIGHT = XXX KG” for metric system)

2.You may press UP or DOWN keys to adjust the weight

3.After weight adjustment, the message display will switch to display “PRESS ENTER” to indi- cate next step. Press ENTER to accept and enter Time adjustment.

Enter your workout time:

1.The message window will fl ash a message of “ENTER TIME”, then “TIME = 30 MIN” and the 30 will be blinking.

2.You may press UP or DOWN keys to adjust the time. When the time setting reaches 60 min- utes, the display will show “TIME = 1HR 00MIN” instead.

3.After weight adjustment, the message display will switch to display “PRESS ENTER” to indi- cate next step. Press ENTER to accept and enter the profi le modifi cation mode.

Modify Profile:

1.The message window will display a message of “MODIFY PROFILE”.

2.You may press UP or DOWN key to modify the profi le from level 1 to level 16. The Dot matrix will adjust accordingly.

3.After each segment is adjusted to the preferred resistance level press ENTER key to move to the next segment.

4.The message “PRESS ENTER OR START” will be displayed during the modifi cation of the profi le indicating that you can press the ENTER key to continue modifying the Profi le or the START/STOP key to skip the modifi cation process and go in to the program.

Or press the START/STOP key to accept current default values and begin the workout

Default time = 30 minutes

Default Intensity = preset level as shown in dot matrix profi le

Age and weight will be what was enter and saved in a previous workout

38

900Ub.Sr OM.R1.indd 38-39

Workout Programs (Continued)

During the Program

Once the Enter or Start key is pressed, the Warm Up will be active. See Warm Up mode section for de- tails.

Main Display

As soon as the program will begins, the Dot Matrix will activate and the 1st segment of the program’s profi le will start blinking

If there is a valid Heart rate signal being detected a heart shape will start blinking and the Heart rate graph will light up with the percentage of maximum heart rate.

The message “Time” will light up in the date display and the Time will start counting down. To switch the data being displayed press the DISPLAY key to select from Time, Calories, Pulse and Distance and to turn on and off the scan function.

Message/Data Display

As soon as the program begins. The message display will turn into workout data display and display four default data: Time, Level, Pulse & Calories and the LED on top of the Data Display key will be lit.

Press the DATA DISPLAY buttons to switch the display to “RPM, Speed, Distance & Watts”. The LED on the bottom of the key will light up.

Adjustment

Press UP or DOWN key to adjust the intensity level from L1 to L16. The dot matrix window will up- date the intensity profi le accordingly and save the change if you press the ENTER key.

Ending the Program

When program time is up or START/STOP key is pressed, this program will end and Cool Down will be active.

The message display will fl ash a message “PROGRAM ENDED”&”COOL DOWN”. See Cool Down for details.

START/STOP key could be pressed to re-start the Strength program again.

START/STOP key could be pressed and held for 2 seconds to skip the Cool Down and activate the Workout Summary immediately.

Pause, Reset, Switch or Save a program

See Console Operating Tips section for details, page 16

39

6/11/2008 9:56:26 AM

Image 19
Contents Purchasers Reference Information Table of ContentsIntroduction Safety Instructions and Warnings900Ub Upright Assembly Instructions 900Ub Upright Assembly DrawingTransformer Assembly 900Sr Recumbent Assembly DrawingHandlebar Assembly Console Assembly900Sr Recumbent Assebly Instructions Seat AssemblyRear Handle Bar Assembly Pedals AssemblyQuantity & Quality BMI = weight lb/ height² in xWorkout Guidelines Maximum Heart Rate & Training ZoneOperating Tips ConsoleGlossary of Terms Pulse Hand Grips StandardDefault Values Console Layout Audio Function KeysAudio Warm Up Workout ProgramsCool Down Quick Start Program Default ValuesPause, Reset, or Switch programs Workout SummaryRandom ManualIntervals Hill Climb Heart Rate Monitoring Device Must be Used for this Program Fitness Test11/2008 95626 AM Custom Trainer StrengthModify Profile Target HR HR Interactive ProgramsHeart Rate Monitoring Device Must be Used for this Program HR IntervalsMaintenance Domestic Warranty Information 900Ub.Sr OM.R1.indd 11/2008 95628 AM IMPORTANT! IMPORTANT! IMPORTANT! Important Warranty Card