Whirlpool W10097001A-SP, W10096987A Optional 3-wire Connection, Connect external ground wire

Page 11

6. Connect neutral wire

B

C

Place hooked end of neutral wire (white or center) (C) of direct wire cable under center terminal block screw (B). Squeeze hooked end together. Tighten screw.

7. Connect remaining wires

2. Connect neutral ground wire and neutral wire

B

C

E

Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of power supply cord or cable under center, silver-colored terminal block screw (B). Tighten screw.

3. Connect remaining wires

Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to

Venting Requirements.

Optional 3-wire Connection

You must verify with a qualified electrician that this grounding method is acceptable before connecting.

1. Prepare to connect neutral ground wire and neutral wire

A

B

E

Remove center, silver-colored terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A).

Place hooked ends of remaining wires under outer terminal block screws (hooks facing right). Tighten screws.

4. Connect external ground wire

A

G

Connect a separate copper ground wire (G) from the external ground conductor screw (A) to an adequate ground. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to

Venting Requirements.

11

Image 11
Contents Table of Contents Tools needed Tools and PartsParts needed Installation clearancesLocation Requirements Parts supplied all modelsIt is your responsibility Minimum spacing for recessed area or closet installationElectrical Requirements Minimum Required SpacingIf your outlet looks like this Install Leveling LegsPrepare dryer for leveling legs Screw in leveling legsRemove terminal block cover Wire direct connection Go to stepsElectrical Connection Choose electrical connection typeWire Power Supply Cord Connection Power Supply Cord ConnectionRemove center screw Connect ground wireConnect remaining wires Connect neutral wireWire Direct Wire Connection Direct Wire ConnectionVenting Requirements Prepare your 3-wire cable for direct connectionConnect external ground wire Optional 3-wire ConnectionElbows Venting RequirementsRigid metal vent Exhaust hoodsVenting Kits Alternate installations for close clearancesRecommended exhaust installations Plan Vent SystemInstall exhaust hood Install Vent SystemVent System Chart Vent System Chart Long Vent Models OnlyLevel Dryer Complete Installation ChecklistConnect Vent Lift door off top screws Reverse Door Swing OptionalPlace towel on dryer Remove bottom screwsSuper Wide Side-Swing Door Check door strike alignmentRemove screws from hinges Flip door over Remove screws from door Attach door hingesRotate outer door Remove door strikeInsert screws in hinge holes on dryer cabinet TroubleshootingW10096987A W10097001A-SP