Whirlpool W10097001A-SP Location Requirements, Parts supplied all models, Parts needed

Page 3

 

If using a power supply cord:

 

Use a UL listed power supply cord kit marked for use with

 

clothes dryers. The kit should contain:

 

A UL listed 30-amp power supply cord, rated 120/240 volt

 

 

minimum. The cord should be type SRD or SRDT and be

 

 

at least 4 ft. (1.22 m) long. The wires that connect to the

1/4" nut driver

Vent clamps

dryer must end in ring terminals or spade terminals with

upturned ends.

(recommended)

 

A UL listed strain relief.

 

Adjustable wrench that opens to 1" (25 mm) or hex-head socket wrench

Utility knife

Location Requirements

Tape measure

Level

Pliers

Caulking gun and compound (for installing new exhaust vent)

You will need:

A location allowing for proper exhaust installation.

 

See “Venting Requirements.”

A separate 30 amp circuit.

If you are using power supply cord, a grounded electrical

 

outlet located within 2 ft. (610 mm) of either side of dryer.

 

See “Electrical Requirements.”

A sturdy floor to support the total weight (dryer and load)

 

of 200 lbs. (90.7 kg). The combined weight of a companion

Parts supplied (all models):

Leveling legs (4)

Parts package is located in dryer drum. Check that all parts are included.

Parts needed:

Check local codes. Check existing electrical supply and venting, and read “Electrical Requirements” and “Venting Requirements” before purchasing parts.

Mobile home installations require metal exhaust system hardware, available for purchase from the dealer from whom you purchased your dryer. For further information, please reference the “Assistance or Service” section of the Dryer

User Instructions.

appliance should also be considered.

Level floor with maximum slope of 1" (25 mm) under entire

dryer. (If slope is greater than 1" [25 mm], install Extended

Dryer Feet Kit, Part Number 279810.) If not level, clothes

may not tumble properly and automatic sensor cycles may

not operate correctly.

Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

Installation clearances:

The location must be large enough to allow the dryer door to open fully.

3

Image 3
Contents Table of Contents Tools needed Tools and PartsParts needed Installation clearancesLocation Requirements Parts supplied all modelsIt is your responsibility Minimum spacing for recessed area or closet installationElectrical Requirements Minimum Required SpacingIf your outlet looks like this Install Leveling LegsPrepare dryer for leveling legs Screw in leveling legsRemove terminal block cover Wire direct connection Go to stepsElectrical Connection Choose electrical connection typeWire Power Supply Cord Connection Power Supply Cord ConnectionRemove center screw Connect ground wireConnect remaining wires Connect neutral wireWire Direct Wire Connection Direct Wire ConnectionVenting Requirements Prepare your 3-wire cable for direct connectionConnect external ground wire Optional 3-wire ConnectionElbows Venting RequirementsRigid metal vent Exhaust hoodsVenting Kits Alternate installations for close clearancesRecommended exhaust installations Plan Vent SystemInstall exhaust hood Install Vent SystemVent System Chart Vent System Chart Long Vent Models OnlyComplete Installation Checklist Connect VentLevel Dryer Lift door off top screws Reverse Door Swing OptionalPlace towel on dryer Remove bottom screwsCheck door strike alignment Remove screws from hingesSuper Wide Side-Swing Door Flip door over Remove screws from door Attach door hingesRotate outer door Remove door strikeInsert screws in hinge holes on dryer cabinet TroubleshootingW10096987A W10097001A-SP