Whirlpool W10097001A-SP, W10096987A installation instructions Wire Power Supply Cord Connection

Page 7

Power Supply Cord Connection

Power supply cord strain relief

1. Attach power supply cord strain relief

A

B

C

D

Remove the screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections (C) into the hole (B) below the terminal block opening so that one tab is pointing up (A) and the other is pointing down (D), and hold in place. Tighten strain relief screws just enough to hold the two clamp sections (C) together.

2. Attach power supply cord to strain relief

Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.

For 3-wire Power Supply Cord Connection, see page 8.

For 4 wire Power Supply Cord Connection, continue to step 3 on this page.

4-wire Power Supply Cord Connection

IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.

A

B

 

F

 

 

 

 

C D

E

G

A.4-wire receptacle (NEMA type 14-30R)

B.4-prong plug

C.Ground prong

D.Neutral prong

E.Spade terminals with upturned ends

F.3/4" (19 mm) UL listed strain relief

G.Ring terminals

3.Prepare to connect neutral ground wire and neutral wire.

A

B

E

Remove center, silver-colored terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A).

4. Connect neutral ground wire and neutral wire

C

B

E

Connect neutral ground wire (E) and neutral wire (white or center) (C) of power supply cord under center, silver-colored terminal block screw (B). Tighten screw.

7

Image 7
Contents Table of Contents Tools needed Tools and PartsParts needed Installation clearancesLocation Requirements Parts supplied all modelsIt is your responsibility Minimum spacing for recessed area or closet installationElectrical Requirements Minimum Required SpacingIf your outlet looks like this Install Leveling LegsPrepare dryer for leveling legs Screw in leveling legsRemove terminal block cover Wire direct connection Go to stepsElectrical Connection Choose electrical connection typeWire Power Supply Cord Connection Power Supply Cord ConnectionRemove center screw Connect ground wireConnect remaining wires Connect neutral wireWire Direct Wire Connection Direct Wire ConnectionVenting Requirements Prepare your 3-wire cable for direct connectionConnect external ground wire Optional 3-wire ConnectionElbows Venting RequirementsRigid metal vent Exhaust hoodsVenting Kits Alternate installations for close clearancesRecommended exhaust installations Plan Vent SystemInstall exhaust hood Install Vent SystemVent System Chart Vent System Chart Long Vent Models OnlyConnect Vent Complete Installation ChecklistLevel Dryer Lift door off top screws Reverse Door Swing OptionalPlace towel on dryer Remove bottom screwsRemove screws from hinges Check door strike alignmentSuper Wide Side-Swing Door Flip door over Remove screws from door Attach door hingesRotate outer door Remove door strikeInsert screws in hinge holes on dryer cabinet TroubleshootingW10096987A W10097001A-SP