Miele T 9822 installation instructions Electrical connection, Grounding Instructions

Page 13

Electrical connection

￿GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance. This appliance is equipped with a cord having an equipment grounding conductor and a grounding plug. The dryer, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Codes ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

WARNING – Improper connection of the equipment grounding conductor can result in a risk of electric shock.

Check with a qualified electrician, service representative or personnel if you are in doubt as to whether the appliance is properly grounded.

￿WARNING – This dryer is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding terminal from this plug.

Do not modify the plug! If it will not fit the outlet, have a proper outlet installed by a qualified electrician.

The dryer is supplied with a 5’ 7"

(1.7 m) 3x14 AWG cord and a NEMA 5-15 P plug, ready for connection to a 120 V, 60 Hz, 15 A AC power supply.

￿Plug the machine into a proper outlet.

If the plug does not fit, have a proper outlet installed by a qualified electrician.

13

Image 13
Contents Installation Instructions T 9822 Gas Dryer Page What to do if YOU Smell GAS Contents Massachusetts Installation and connectionSave These Instructions Front view InstallationStand Rear InstallationInstallation site Confined door openings Confined space installationLevel the dryer Transporting the dryer to the installation siteChanging the position of the exhaust connection Determining the position of the exhaust connectionGrounding Instructions Electrical connectionGas type Gas connectionGas connection distances Gas supplyDo not Overtighten Never USE AN Open Flame to Test for GAS Leaks Exhaust ducting and connections DuctingHow to calculate the effective duct length Tips about the ductwork Smooth metal duct Additional duct lengths 4 100 mm rigid pipe onlyElbow 90 sharp Concertina bendRigid pipe Duct length ExampleTotal duct LengthExhaust connection on left or right Wall connection example Window connection exampleDryer top view Direct wall connectionDisposal of the packing materials Caring for the environmentDisposal of an appliance