Miele T 9822 installation instructions Gas connection, Gas type

Page 14

Gas connection

￿WARNING

Installation and service must be performed by a qualified installer, service agency or gas supplier.

In Massachusetts a licensed plumber / gas fitter is required.

This appliance must be installed with its own shut off valve in the same room. The valve must be easily accessible to the consumer to turn on or shut off the gas supply after the appliance is installed.

During any pressure testing of the gas system this appliance must be disconnected from the gas supply by closing its individual manual shut off valve.

Any pipe connections must be made using a thread sealant approved for gas connections. Failure to correctly install these items could lead to a gas leak and subsequent explosion.

The gas installation must be made in accordance with local codes or, in the absence of local codes, with

-National Fuel Gas Code, ANSI Z223.1/NFPA 54 for USA

or

-Natural Gas and Propane Installation Code,

CSA B149.1 for Canada.

Gas type

The gas dryer is equipped for connection to a NATURAL GAS supply.

The maximum heat output is 19,500 BTU/H (5,7 kW).

Minimum gas supply pressure to obtain the required gas input is:

0.15psi (4" WC) for natural gas

0.29psi (8" WC) for LP gas.

Maximum gas supply pressure before the gas pressure regulator

0.37psi (10" WC) for natural gas

0.46psi (13" WC) for LP gas.

14

Image 14
Contents Installation Instructions T 9822 Gas Dryer Page What to do if YOU Smell GAS Contents Installation and connection MassachusettsSave These Instructions Stand InstallationFront view Installation RearInstallation site Confined space installation Confined door openingsTransporting the dryer to the installation site Level the dryerDetermining the position of the exhaust connection Changing the position of the exhaust connectionElectrical connection Grounding InstructionsGas connection Gas typeGas supply Gas connection distancesDo not Overtighten Never USE AN Open Flame to Test for GAS Leaks Ducting Exhaust ducting and connectionsHow to calculate the effective duct length Tips about the ductwork Elbow 90 sharp Additional duct lengths 4 100 mm rigid pipe onlySmooth metal duct Concertina bendTotal duct ExampleRigid pipe Duct length LengthExhaust connection on left or right Window connection example Wall connection exampleDirect wall connection Dryer top viewDisposal of an appliance Caring for the environmentDisposal of the packing materials