Alliance Laundry Systems HF575, HF900, HF455, HF730 instruction manual Water connection, Water drain

Page 25

4

Water connection

The machine is delivered with hoses with 3/4" connections (HF455-575) and with 1x3/4" + 3x1" connections (HF730-900). These hoses fit the water inlet valves of the machine and the main water inlet taps. All the inlet valves have to be connected.

To ensure the optimal functioning of the water inlet valves, the water pressure on the inlet should be between 3 and 5 bar (40 and 80 psi). If the pressure is too low, the cycle time will increase considerably.

Inlet flow capacity per minute (gallons / liters): 7.93 + 13.2 / 30 + 50.

In case of boiler fed machines, a minimum of hot water of 90°C - 194°F should be available per unit. (See Table 1)

MODEL

Min Contents Boiler

METRIC

US

 

For the HF455, IHF455, IHF100, CHF100

350 l.

12.36 ft³

For the HF575, IHF575, IHF135, CHF135

445 l.

15.72 ft³

For the HF730, IHF730, IHF165, CHF165

566 l.

19.99 ft³

For the HF900, IHF900

566 l.

19.99 ft³

Table 1

To comply with the WRAS water regulations: an 'approved' single check valve or some other no less effective backflow prevention device shall be fitted at the point of connection(s) between the supply and the fitting (IRN R150).

Water drain

The machine is equipped with a drain valve with 3" outer diameter (80 mm) for HF455- 575 and with 2x3" outer diameter (2x80 mm) for HF730-900. This drain valve should be connected to the drain by means of the drain elbow which is delivered with the machine.

The diameter of the main drain should be adapted to the water flow and the number of machines. It should be sufficient to handle at least 80 l/min - 21.13 gal./min

(HF455-575) and 160 l/min - 42.26 gal./min (HF730-900) per machine.

It is necessary to connect the main drain at least on one side to an open air-brake to allow ventilation.

When the main drain has not been sufficiently deodorized, every machine should be installed separately with a deodorizer.

25

Image 25
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Build-up Model NumbersSafety Safety and Environmental InformationsDisposal of Unit EnvironmentalExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data HF455, IHF455, IHF100, CHF100 Technical data and dimensionsDimensions HF455, IHF455, IHF100, CHF100 Technical data HF575, IHF575, IHF135, CHF135 Dimensions HF575, IHF575, IHF135, CHF135 Technical data HF730, IHF730, IHF165, CHF165 Dimensions HF730, IHF730, IHF165, CHF165 Technical data HF900, IHF900 Dimensions HF900, IHF900 Removal of the transport safety Installation and Connection InstructionsSurface Ø20 1270 1180 1273 1185 Mounting Bolt Hole Locations for machines, HF900, IHF900 Water drain Water connectionImportant Do not use fuses in place of a circuit breaker Electrical InstallationGrounding Instructions Machine Power Cable Connections Main power connectionConnection label Page Boiler Fed/Steam Heat Electric Heat Electrical Specifications HF455, IHF455, IHF100, CHF100Alternative Electric Heat Options Liters / 135 pounds Electrical Specifications HF575, IHF575, IHF135, CHF135Liters / 165 pounds Electrical Specifications HF730, IHF730, IHF165, CHF165Liters / 200 pounds Electrical Specifications HF900, IHF900Automatic lubricator Connection of the liquid soap hoses Liquid soap connection optionWith an external tension 24V DC See Label Label With direct steam injection into the machine See Table Steam connectionInternal connections of the electrical heating Technical remarksOpening the door in case of an emergency Out of balance switchEnd of day General maintenance Periodical maintenance Maintenance instruction of the machineHF455 Annual maintenanceHF575 HF730Nameplate Contact InformationNameplate Location Replacement Parts Repair and after-sales service