4
Water connection
The machine is delivered with hoses with 3/4" connections
To ensure the optimal functioning of the water inlet valves, the water pressure on the inlet should be between 3 and 5 bar (40 and 80 psi). If the pressure is too low, the cycle time will increase considerably.
Inlet flow capacity per minute (gallons / liters): 7.93 + 13.2 / 30 + 50.
In case of boiler fed machines, a minimum of hot water of 90°C - 194°F should be available per unit. (See Table 1)
MODEL | Min Contents Boiler | ||
METRIC | US | ||
| |||
For the HF455, IHF455, IHF100, CHF100 | 350 l. | 12.36 ft³ | |
For the HF575, IHF575, IHF135, CHF135 | 445 l. | 15.72 ft³ | |
For the HF730, IHF730, IHF165, CHF165 | 566 l. | 19.99 ft³ | |
For the HF900, IHF900 | 566 l. | 19.99 ft³ |
Table 1
To comply with the WRAS water regulations: an 'approved' single check valve or some other no less effective backflow prevention device shall be fitted at the point of connection(s) between the supply and the fitting (IRN R150).
Water drain
The machine is equipped with a drain valve with 3" outer diameter (80 mm) for HF455- 575 and with 2x3" outer diameter (2x80 mm) for
The diameter of the main drain should be adapted to the water flow and the number of machines. It should be sufficient to handle at least 80 l/min - 21.13 gal./min
It is necessary to connect the main drain at least on one side to an open
When the main drain has not been sufficiently deodorized, every machine should be installed separately with a deodorizer.