Alliance Laundry Systems HF730, HF900 Electrical Specifications HF575, IHF575, IHF135, CHF135

Page 31

4

WARNING

The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment.

Electrical Specifications HF575, IHF575, IHF135, CHF135

575 liters / 135 pounds

 

 

 

 

 

Boiler Fed/Steam Heat

 

Electric Heat

 

Code

Voltage

Cycle

Phase

Wire

Full Load Amps

 

Recommended Circuit Breaker (US-market)

AWG/mm2

kW Standard Heating Elements

Full Load Amps

 

Recommended Circuit Breaker

AWG/mm2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

US

NON-US

 

 

 

US

NON-US

 

N

440-480

50/60

3

3+PE

27

30

32

10/6.0

9x4 kW

79

N/A

80

4/25

P

380-415

50/60

3

3+N+PE

27

30

32

10/6.0

79

N/A

80

4/25

 

Q

200-240

50/60

3

3+PE

52

60

60

8/10.0

9x3 kW

120

N/A

125

2/40

X

200-240

50/60

1/3

2/3+PE

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

 

Alternative Electric Heat Options

N

440-480

50/60

3

3+PE

 

 

 

 

 

66

N/A

70

4/25

P

380-415

50/60

3

3+N+PE

 

 

 

 

9x3 kW

66

N/A

70

4/25

Q

200-240

50/60

3

3+PE

 

 

 

 

79

N/A

80

4/25

 

 

 

 

 

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

N/A

N/A

N/A

N/A

 

 

 

 

 

 

 

Table 3

 

 

 

 

 

 

31

Image 31
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Build-up Model NumbersSafety Safety and Environmental InformationsDisposal of Unit EnvironmentalExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data HF455, IHF455, IHF100, CHF100 Technical data and dimensionsDimensions HF455, IHF455, IHF100, CHF100 Technical data HF575, IHF575, IHF135, CHF135 Dimensions HF575, IHF575, IHF135, CHF135 Technical data HF730, IHF730, IHF165, CHF165 Dimensions HF730, IHF730, IHF165, CHF165 Technical data HF900, IHF900 Dimensions HF900, IHF900 Removal of the transport safety Installation and Connection InstructionsSurface Ø20 1270 1180 1273 1185 Mounting Bolt Hole Locations for machines, HF900, IHF900 Water drain Water connectionImportant Do not use fuses in place of a circuit breaker Electrical InstallationGrounding Instructions Machine Power Cable Connections Main power connectionConnection label Page Boiler Fed/Steam Heat Electric Heat Electrical Specifications HF455, IHF455, IHF100, CHF100Alternative Electric Heat Options Liters / 135 pounds Electrical Specifications HF575, IHF575, IHF135, CHF135Liters / 165 pounds Electrical Specifications HF730, IHF730, IHF165, CHF165Liters / 200 pounds Electrical Specifications HF900, IHF900Automatic lubricator Connection of the liquid soap hoses Liquid soap connection optionWith an external tension 24V DC See Label Label With direct steam injection into the machine See Table Steam connectionInternal connections of the electrical heating Technical remarksOpening the door in case of an emergency Out of balance switchEnd of day General maintenance Periodical maintenance Maintenance instruction of the machineHF730 Annual maintenanceHF455 HF575Nameplate Contact InformationNameplate Location Replacement Parts Repair and after-sales service