Alliance Laundry Systems HF900, HF575 Electrical Specifications HF455, IHF455, IHF100, CHF100

Page 30

4

WARNING

The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment.

Electrical Specifications HF455, IHF455, IHF100, CHF100

455 liters / 100 pounds

 

 

 

 

 

Boiler Fed/Steam Heat

 

Electric Heat

 

Code

Voltage

Cycle

Phase

Wire

Full Load Amps

 

Recommended Circuit Breaker (US-market)

AWG/mm2

kW Standard Heating Elements

Full Load Amps

 

Recommended Circuit Breaker

AWG/mm2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

US

NON-US

 

 

 

US

NON-US

 

N

440-480

50/60

3

3+PE

22

30

32

10/6.0

9x4 kW

74

N/A

80

4/25

P

380-415

50/60

3

3+N+PE

22

30

32

10/6.0

74

N/A

80

4/25

 

Q

200-240

50/60

3

3+PE

36

40

40

8/10.0

9x3 kW

104

N/A

125

2/40

X

200-240

50/60

1/3

2/3+PE

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

 

Alternative Electric Heat Options

N

440-480

50/60

3

3+PE

 

 

 

 

 

61

N/A

70

4/25

P

380-415

50/60

3

3+N+PE

 

 

 

 

9x3 kW

61

N/A

70

4/25

Q

200-240

50/60

3

3+PE

 

 

 

 

104

N/A

125

2/40

 

 

 

 

 

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

N/A

N/A

N/A

N/A

 

 

 

 

 

 

 

Table 2

 

 

 

 

 

 

30

Image 30
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Model Numbers Build-upSafety and Environmental Informations SafetyEnvironmental Disposal of UnitExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data and dimensions Technical data HF455, IHF455, IHF100, CHF100Dimensions HF455, IHF455, IHF100, CHF100 Technical data HF575, IHF575, IHF135, CHF135 Dimensions HF575, IHF575, IHF135, CHF135 Technical data HF730, IHF730, IHF165, CHF165 Dimensions HF730, IHF730, IHF165, CHF165 Technical data HF900, IHF900 Dimensions HF900, IHF900 Installation and Connection Instructions Removal of the transport safetySurface Ø20 1270 1180 1273 1185 Mounting Bolt Hole Locations for machines, HF900, IHF900 Water connection Water drainElectrical Installation Important Do not use fuses in place of a circuit breakerGrounding Instructions Main power connection Machine Power Cable ConnectionsConnection label Page Electrical Specifications HF455, IHF455, IHF100, CHF100 Boiler Fed/Steam Heat Electric HeatAlternative Electric Heat Options Electrical Specifications HF575, IHF575, IHF135, CHF135 Liters / 135 poundsElectrical Specifications HF730, IHF730, IHF165, CHF165 Liters / 165 poundsElectrical Specifications HF900, IHF900 Liters / 200 poundsAutomatic lubricator Liquid soap connection option Connection of the liquid soap hosesWith an external tension 24V DC See Label Label Steam connection With direct steam injection into the machine See TableTechnical remarks Internal connections of the electrical heatingOut of balance switch Opening the door in case of an emergencyMaintenance instruction of the machine End of day General maintenance Periodical maintenanceHF575 Annual maintenanceHF455 HF730Contact Information NameplateNameplate Location Replacement Parts Repair and after-sales service