Alliance Laundry Systems HF730 Technical remarks, Internal connections of the electrical heating

Page 39

Technical remarks

 

 

 

 

 

 

6

Internal connections of the electrical heating

 

 

 

 

1 AC

 

 

 

 

 

 

 

Heating

 

R5

 

 

 

 

 

3kw

 

LC1D0901

 

 

 

 

 

 

Table 7

 

 

 

 

3 AC

 

 

 

 

 

 

 

Heating

 

 

3x230V

R5

3x400V

R5

 

 

 

 

4,2kw

 

3x1,4kw

See Label 14

LC1D0901

See Label 15

LC1D0901

 

6kw

 

3x2kw

See Label 14

LC1D0901

See Label 15

LC1D0901

 

9kw

 

3x3kw

See Label 14

LC1D1810

See Label 15

LC1D0901

 

12kw

 

3x4kw

--------

--------

See Label 14

LC1D0901

 

12kw

 

3x2kw

See Label 14

LC1D1810

See Label 15

LC1D1810

 

 

 

3x2kw

See Label 14

LC1D1810

 

 

 

15kw

 

3x2kw

See Label 14

LC1D1810

See Label 15

LC1D1810

 

 

 

3x3kw

See Label 14

LC1D1810

 

 

 

18kw

 

3x3kw

See Label 14

LC1D1810

See Label 15

LC1D1810

 

 

 

3x3kw

See Label 14

LC1D1810

 

 

 

21kw

 

3x3kw

--------

--------

See Label 15

LC1D1810

 

 

 

3x4kw

 

 

See Label 14

LC1D1810

 

24kw

 

3x4kw

--------

--------

See Label 14

LC1D1810

 

 

 

3x4kw

 

 

See Label 14

LC1D1810

 

27kw

 

3x3kw

See Label 14

LC1D1810

See Label 15

LC1D1810

 

 

 

3x3kw

See Label 14

LC1D1810

See Label 15

LC1D1810

 

 

 

3x3kw

See Label 14

LC1D1810

See Label 15

LC1D1810

 

36kw

 

3x4kw

 

 

See Label 14

LC1D1810

 

 

 

3x4kw

--------

--------

See Label 14

LC1D1810

 

 

 

3x4kw

 

 

See Label 14

LC1D1810

Table 8

B = Black

Br = Brown

Gy = Grey

Bu = Blue

R = Red

W = White

Label 14

Label 15

"Delta" configuration

"WYE" configuration

NOTE:

Other executions are available as options.

39

Image 39
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Build-up Model NumbersSafety Safety and Environmental InformationsDisposal of Unit EnvironmentalExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data HF455, IHF455, IHF100, CHF100 Technical data and dimensionsDimensions HF455, IHF455, IHF100, CHF100 Technical data HF575, IHF575, IHF135, CHF135 Dimensions HF575, IHF575, IHF135, CHF135 Technical data HF730, IHF730, IHF165, CHF165 Dimensions HF730, IHF730, IHF165, CHF165 Technical data HF900, IHF900 Dimensions HF900, IHF900 Installation and Connection Instructions Removal of the transport safetySurface Ø20 1270 1180 1273 1185 Mounting Bolt Hole Locations for machines, HF900, IHF900 Water drain Water connectionImportant Do not use fuses in place of a circuit breaker Electrical InstallationGrounding Instructions Main power connection Machine Power Cable ConnectionsConnection label Page Electrical Specifications HF455, IHF455, IHF100, CHF100 Boiler Fed/Steam Heat Electric HeatAlternative Electric Heat Options Liters / 135 pounds Electrical Specifications HF575, IHF575, IHF135, CHF135Liters / 165 pounds Electrical Specifications HF730, IHF730, IHF165, CHF165Liters / 200 pounds Electrical Specifications HF900, IHF900Automatic lubricator Connection of the liquid soap hoses Liquid soap connection optionWith an external tension 24V DC See Label Label With direct steam injection into the machine See Table Steam connectionInternal connections of the electrical heating Technical remarksOpening the door in case of an emergency Out of balance switchEnd of day General maintenance Periodical maintenance Maintenance instruction of the machineHF730 Annual maintenanceHF455 HF575Contact Information NameplateNameplate Location Replacement Parts Repair and after-sales service