Water connection

The machine is delivered with hoses with 3/4" connections. These hoses fit the water inlet valves of the machine and the main water inlet taps. All the inlet valves have to be connected. To ensure the optimal functioning of the water inlet valves, the water pressure on the inlet should be between 3 and 5 bar (40 and 80 psi). If the pressure is too low, the cycle time will increase considerably.

International inlet flow capacity per minute (gallons / liters): 4.23 / 16.

US inlet flow capacity per minute (gallons / liters): 5.28 / 20.

In case of boiler fed machines, a minimum of hot water of 90°C - 194°F should be available per unit. (See Table 1)

MODEL

Min Contents Boiler

METRIC

US

 

For the HC60, IHC012, IHC060

46 l.

1.62 ft³

For the HC65, IHC014, IHC065

55 l.

1.94 ft³

For the HC75, IHC018, CHC018, IHC075

65 l.

2.29 ft³

For the HC100, IHC025, CHC025, IHC100

80 l.

2.82 ft³

For the HC135, IHC030, IHC135

100 l.

3.53 ft³

For the HC165, IHC035, CHC035, IHC165

120 l.

4.23 ft³

Table 1

To comply with the WRAS water regulations: an 'approved' single check valve or some other no less effective backflow prevention device shall be fitted at the point of connection(s) between the supply and the fitting (IRN R150).

Water drain

The machine is equipped with a drain valve with 2" outer diameter (50 mm). This drain valve should be connected to the drain by means of the drain elbow which is delivered with the machine.

The diameter of the main drain should be adapted to the water flow and the number of machines. It should be sufficient to handle at least 80 l/min - 21.13 gal./min per machine.

It is necessary to connect the main drain at least on one side to an open air-brake to allow ventilation.

34

Image 34
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Page Model Numbers Build-up Model numbersPage Safety and Environmental Informations SafetyEnvironmental Disposal of UnitExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data and dimensions Technical data HC60, IHC012, IHC060Dimensions HC60, IHC012, IHC060 Technical data HC65, IHC014, IHC065 Dimensions HC65, IHC014, IHC065 Technical data HC75, IHC018, CHC018, IHC075 Dimensions HC75, IHC018, CHC018, IHC075 Technical data HC100, IHC025, CHC025, IHC100 Dimensions HC100, IHC025, CHC025, IHC100 Technical data HC135, IHC030, IHC135 Dimensions HC135, IHC030, IHC135 Technical data HC165, IHC035, CHC035, IHC165 Dimensions HC165, IHC035, CHC035, IHC165 Out of balance switch Installation and Connection InstructionsSurface Removal of the transport safety 485 545 530 660 590 650 530 660 590 650 530 660 690 750 530 660 36.5 665 738 648 780 36.5 765 838 648 Water connection Water drainElectrical Installation Important Do not use fuses in place of a circuit breakerGrounding Instructions Machine Power Cable Connections Main power connectionConnection label Page Boiler Fed/Steam Heat Electric Heat Electrical Specifications HC60, IHC012, IHC060Alternative Electric Heat Options Electrical Specifications HC65, IHC014, IHC065 Liters / 14 poundsElectrical Specifications HC75, IHC018, CHC018, IHC075 Liters / 18 poundsElectrical Specifications HC100, IHC025, CHC025, IHC100 Liters / 25 poundsElectrical Specifications HC135, IHC030, IHC135 Liters / 30 poundsElectrical Specifications HC165, IHC035, CHC035, IHC165 Liters / 35 poundsLiquid soap connection option Connection of the liquid soap hosesWith an external tension 24V DC See Label Label Steam connection With direct steam injection into the machine See TableTechnical remarks Internal connections of the electrical heatingGeneral maintenance Periodical maintenance Maintenance instruction of the machineEnd of day Annual maintenance Nameplate Contact InformationNameplate Location Replacement Parts Repair and after-sales service