200-240 Volts, 3-Phase, 3-wire + PE, 50 or 60 Hertz Configuration (Named: Q-Voltage or 3-phase X-Voltage):

With supply power of: 200-240 Volts, 3-phase, 3-wire, after connecting the green/yellow PE ground wire, connect one power

wire to each of the terminals at the bottom of the power contactor switch marked: “L1,L2,L3”.

200-240 volts, 1-Phase, 2-wire + PE, 50 Hertz (called 1-phase, 50 Hz X-voltage):

With supply power of: 200-240 Volts, 1-phase, 2-wire, 50Hz, after connecting the green/yellow PE ground wire, connect the power wire to the “L1” bottom terminal of the power contactor switch and the other wire, identified as the neutral wire, to the bottom terminal of the auxiliary contactor on the power contactor switch marked: “N”.

200-240 volts, 1-Phase, 2-wire + PE, 60 Hertz (called 1-phase, 60 Hz X-voltage):

With supply power of: 200-240 Volts, 1-phase, 2-wire, 60Hz, after connecting the green/yellow PE ground wire, connect one power wire to the “L1” and power wire to the “L2” of the bottom terminals of the power contactor switch.

After connection, check the spin direction. The cylinder must spin in the clockwise direction.

A wrong spin direction can damage the motor and can also cause water to spurt from the soap dispenser.

In case of wrong spin direction: switch the terminal clamps of the motor circuit “R” and “S” of the connecting cable or change the connection at the terminal block switching the L1 and L2 wires.

38

Image 38
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Page Model Numbers Build-up Model numbersPage Safety and Environmental Informations SafetyEnvironmental Disposal of UnitExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data and dimensions Technical data HC60, IHC012, IHC060Dimensions HC60, IHC012, IHC060 Technical data HC65, IHC014, IHC065 Dimensions HC65, IHC014, IHC065 Technical data HC75, IHC018, CHC018, IHC075 Dimensions HC75, IHC018, CHC018, IHC075 Technical data HC100, IHC025, CHC025, IHC100 Dimensions HC100, IHC025, CHC025, IHC100 Technical data HC135, IHC030, IHC135 Dimensions HC135, IHC030, IHC135 Technical data HC165, IHC035, CHC035, IHC165 Dimensions HC165, IHC035, CHC035, IHC165 Surface Installation and Connection InstructionsOut of balance switch Removal of the transport safety 485 545 530 660 590 650 530 660 590 650 530 660 690 750 530 660 36.5 665 738 648 780 36.5 765 838 648 Water connection Water drainElectrical Installation Important Do not use fuses in place of a circuit breakerGrounding Instructions Connection label Main power connectionMachine Power Cable Connections Page Alternative Electric Heat Options Electrical Specifications HC60, IHC012, IHC060Boiler Fed/Steam Heat Electric Heat Electrical Specifications HC65, IHC014, IHC065 Liters / 14 poundsElectrical Specifications HC75, IHC018, CHC018, IHC075 Liters / 18 poundsElectrical Specifications HC100, IHC025, CHC025, IHC100 Liters / 25 poundsElectrical Specifications HC135, IHC030, IHC135 Liters / 30 poundsElectrical Specifications HC165, IHC035, CHC035, IHC165 Liters / 35 poundsLiquid soap connection option Connection of the liquid soap hosesWith an external tension 24V DC See Label Label Steam connection With direct steam injection into the machine See TableTechnical remarks Internal connections of the electrical heatingEnd of day Maintenance instruction of the machineGeneral maintenance Periodical maintenance Annual maintenance Nameplate Location Contact InformationNameplate Replacement Parts Repair and after-sales service