Alliance Laundry Systems HC135, HC65, HC165, HC75, HC100, HC60 instruction manual Annual maintenance

Page 51

B

A

7

Important

-Clean the drainpipe every 6 months in case drain (B) is used.

-The water still being in the drain needs to be drained using drain (A) before cleaning the drainpipe or replacing the exhaust valve.

Annual maintenance

Belt tension:

Verify that the belts are running in the middle of the basket pulley.

Verify the belt tension according to the table below. Belt tension measurements should be taken as close as possible to the center of the belt span (see figure).

Belt tension testing table

Model

Belt

Frequency (Hz)

Tension force (N)

Deflection (mm)

Deflection force

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

at MIN

at MAX

 

 

 

MIN

MAX

MIN

MAX

tension

tension

MAX

HC60

8PJ 1355

107

137

470

766

7

4

40

HC65

8PJ 1355

107

137

470

766

7

4

40

HC75

8PJ 1355

107

137

470

766

7

4

40

HC100

8PJ 1355

107

137

470

766

7

4

40

HC135

10J 1473

75

105

316

618

10,5

6,4

40

HC165

10J 1473

75

105

316

618

10,5

6,4

40

1 Deflection

2 Span length

51

Image 51
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Page Build-up Model numbers Model NumbersPage Safety Safety and Environmental InformationsDisposal of Unit EnvironmentalExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data HC60, IHC012, IHC060 Technical data and dimensionsDimensions HC60, IHC012, IHC060 Technical data HC65, IHC014, IHC065 Dimensions HC65, IHC014, IHC065 Technical data HC75, IHC018, CHC018, IHC075 Dimensions HC75, IHC018, CHC018, IHC075 Technical data HC100, IHC025, CHC025, IHC100 Dimensions HC100, IHC025, CHC025, IHC100 Technical data HC135, IHC030, IHC135 Dimensions HC135, IHC030, IHC135 Technical data HC165, IHC035, CHC035, IHC165 Dimensions HC165, IHC035, CHC035, IHC165 Installation and Connection Instructions Out of balance switchSurface Removal of the transport safety 485 545 530 660 590 650 530 660 590 650 530 660 690 750 530 660 36.5 665 738 648 780 36.5 765 838 648 Water drain Water connectionImportant Do not use fuses in place of a circuit breaker Electrical InstallationGrounding Instructions Main power connection Machine Power Cable ConnectionsConnection label Page Electrical Specifications HC60, IHC012, IHC060 Boiler Fed/Steam Heat Electric HeatAlternative Electric Heat Options Liters / 14 pounds Electrical Specifications HC65, IHC014, IHC065Liters / 18 pounds Electrical Specifications HC75, IHC018, CHC018, IHC075Liters / 25 pounds Electrical Specifications HC100, IHC025, CHC025, IHC100Liters / 30 pounds Electrical Specifications HC135, IHC030, IHC135Liters / 35 pounds Electrical Specifications HC165, IHC035, CHC035, IHC165Connection of the liquid soap hoses Liquid soap connection optionWith an external tension 24V DC See Label Label With direct steam injection into the machine See Table Steam connectionInternal connections of the electrical heating Technical remarksMaintenance instruction of the machine General maintenance Periodical maintenanceEnd of day Annual maintenance Contact Information NameplateNameplate Location Replacement Parts Repair and after-sales service