You must press “Start/Pause/Cancel” button in order the machine starts its program.
Program selection table
Determine the suitable program according to the type, amount, dirtiness level and washing temperature of the laundry by looking at the program selection table.Turn the program
selection knob to the
Program | Laundry type | |
| ||
Cotton 90 | Very dirty, heat resistant cotton, linen | |
Cotton 60* | Normal dirty, heat resistant cotton, linen | |
Cotton 40 | Less dirty or heat resistant cotton | |
Cold (Cotton) | Less dirty or heat resistant cotton | |
Super 40 | Very dirty and heat resistant cotton | |
Synthetic 60 | Normal dirty, heat resistant cotton/syn- | |
thetic compound | ||
| ||
Synthetic 40 | Less dirty or heat resistant cotton/syn- | |
thetic compound | ||
| ||
Synthetic 30 | Very little dirty or heat resistant | |
cotton/synthetic compound | ||
| ||
Cold (Synthetic) | Very little dirty or heat resistant | |
cotton/synthetic compound | ||
| ||
Delicate 30 | Sensitive, Delicate synthetic, cotton | |
compound | ||
| ||
Woolen 40 | Woolens and sensitive compounds with | |
machine washable label | ||
| ||
Cold (Woolen) | Woolens and sensitive compounds with | |
machine washable label | ||
| ||
| Special program for laundries that have | |
Hand Wash 30 | silk, cashmere, | |
| labels. | |
| Special program for very little dirty or small | |
Mini 30 | amounts of laundries (sweat suit, towel | |
| and etc. that are used only for once) | |
Rinsing | Rinsing Program | |
Spin+Pump | Spin + Pump Program |
Maximum Load (kg) | Program Time (min) | Water consumption (lt) | Power consumption (kWh) | Prewash | Rinse Plus | ||
|
|
| |||||
• | • | ||||||
5 | 155 | 45 | 1.70 | ||||
5 | 145 | 49 | 1.14 | • | • | ||
5 | 150 | 45 | 0.65 | • | • | ||
3.5 | 113 | 39 | 0.14 | • | • | ||
5 | 180 | 45 | 0.65 |
|
|
| |
2.5 | 120 | 55 | 0.90 | • | • | ||
2.5 | 125 | 55 | 0.55 | • | • | ||
2.5 | 92 | 50 | 0.28 | • | • | ||
2.5 | 85 | 50 | 0.10 | • | • | ||
2 | 85 | 60 | 0.40 |
|
| • | |
|
|
| |||||
1.5 | 70 | 60 | 0.40 |
|
| • | |
1.5 | 51 | 55 | 0.02 |
|
| • | |
|
|
| |||||
1 | 55 | 50 | 0.21 |
|
|
| |
2.5 | 30 | 40 | 0.16 |
|
|
| |
3.5 | - | 20 | 0.03 |
|
|
| |
3.5 | - | 11 | 0.03 |
|
|
| |
|
|
|
|
|
|
|
• Rinse Hold
•
•
•
•
•
•
•
•
•
•
*Energy Label Program EN 60456:1999 and IEC 60456 Ed.4 2001
Water and power consumption may show differences from the table above depending on the water pressure,
hardness and temperature, environmental temperature, laundry type and amount, auxiliary function selection and changes in the electricity voltage.
11
EN