6. Technical point
3) The other water level data
unit:Khz
The water data unter each conditon |
|
| |
|
|
|
|
1st water supply (only preparation) | 24.60 |
| 1st water supply level to washing tub |
|
|
|
|
Overflow error | 20.50 |
| The water supplied reach 2/3 of door |
|
|
|
|
Bubble | 25.45 |
| Bubble |
detectingatwashing/rinse/dehydrating |
| ||
|
|
| |
Bubble detecting rinse water level | 22.60 |
| The water level which can detect bubbles |
|
|
|
|
Water level which can open door | 24.10 | over | It is possible to open the door |
|
|
| |
Water level which can drive heater | 24.50(3.5 ) | Safety water level of wash heater | |
|
| ℓ |
|
Water level which can reset the drain | 24.50 |
| The water level can be detected after 1st draining |
|
|
|
|
※ If water level is 15KHZ below or 30 KHZ above ,
11