Samsung r1031gws, R1031GWS YLR specifications Cause and treatment

Page 16

8-1. Trouble Diagnosis

 

No

Item

Cause and treatment

 

 

 

- Is the PCB connector connected well?

 

 

 

- Is the voltage normal?

 

 

 

- Is the power supply plug connected well?

 

1

The power is not supplied

- Is the noise filter connected well?

 

- Is the secondary output of the power supply transformation normal?

 

 

 

 

 

 

- Is the fuse disconnected? (option)

 

 

 

ï If above points are not found, the PCB assembly is out of order.

 

 

 

Replace it.

 

 

 

- Is the knob open?

 

 

 

- Did you push START/PAUSE button after selecting the course?

 

2

The water is not supplied.

- Is the water supply valve connected well?

 

- Is the winding of the water supply valve continuous?

 

 

 

- Is the connection and operation of the pressure switch normal?

 

 

 

ï If above points are not found, the PCB assembly is out of order.

 

 

 

Replace it.

 

 

 

- Is the connection and operation of the pressure switch normal?

 

 

The wash does not start though

- Is the pressure switch hose damaged so that the air is leaked?

 

3

- Is the pressure switch hose bent?

 

the water supply is stopped.

- Check the operation of the water level switch.

 

 

 

 

 

ï If above points are not found, the PCB assembly is out of order.

 

 

 

Replace it.

 

 

 

 

 

 

 

- Is the belt connected well?

 

 

 

- Is the winding of the motor continuous?

 

4

The drum does not rotate during

(Rotor winding, stator winding, generator)

 

washing.

- Is the motor protector normal?

 

 

 

 

 

ï If above points are not found, the PCB assembly is out of order.

 

 

 

Replace it.

 

5

The drum rotates by one direction

- The PCB assembly is out of order. Replace it.

 

during washing. (The drum rotates

 

 

to one direction for SPIN.)

(Inversion relay open trouble)

 

 

 

 

 

 

 

 

 

 

- Is the drainage hose bent?

 

6

Drainage problem.

- Is the winding of the drainage pump continuous?

 

- Is the drain filter clogged by the waste?

 

 

 

ï If above points are not found, the PCB assembly is out of order.

 

 

 

Replace it.

 

7

Dehydration problem.

- The unbalance is detected.

 

- Put in the laundry uniformly and start again.

 

 

 

 

 

 

 

 

 

 

- Is the pulley nut loosen?

 

8

Abnormal noise during SPIN.

- Is the transport safety device removed?

 

- Is the product installed on the level and stable place?

 

 

 

 

 

 

(Little noise may be generated during the high-speed SPIN.)

 

 

 

<When the leak breaker and current breaker is installed separately>

 

 

 

- When the leak breaker is down, check and make the earth of the outlet.

 

 

Leak breaker or current/leak

- When the current is down, the current is leaked.

 

9

<Is the breaker down when the leak/current breaker is combined?>

 

breaker is down during washing.

- Check the rated capacity of the current and leak breaker.

 

 

 

 

 

The current breaker may be down due to the lack of the current when the

 

 

 

wash machine and other apparatus are used.

 

 

 

In this case, execute the cold water wash to check whether the current capacity is lack.

 

 

 

- Is the wash heater terminal unplugged?

 

10

The heating is not executed.

- Is the wash heater normal?

 

- If above points are not found, the PCB assembly is out of order.

 

 

 

 

 

 

Replace it.

 

 

 

 

 

 

 

 

15

Image 16
Contents Washing Machine Do not allow the customer to repair the product Specifications Power ConsumptionSafety Devices Overview of the Washing Machine Overview of the control panel Auto power S/W off function Main functionDoor open function No spin functionPower-out compensation function Water heater Error functionFuzzy washing function weight-sensing Bubble -detecting functionUnbalance detecting & laundry balance positioning system Final dehydrating r.p.m at each course Water level data at each courseOther water level data General Error Function ASSí Y Pressure S/W ErrorMotor Triac short Error Tacho ErrorThermistor error Power Supply Plug Trouble DiagnosisCause and treatment Problem Checkking And Method Of Pcb Part Of Power SourceReset Part Interrupt PartChecking The Part Of An Oscillator Micom Number, 9 Is 5Voltage? Confirm The Driving Part Of Motor Checking The Tacho Part Test Mode Driving Compartment Test ModeDesignation of Main Components Door safety DeviceNormal / Reverse Revolution of Motor and R. P. M. Control Heater Detergent tub and water supply valueShock absorber and buffer spring Hot water valve1 wayASSY-TUB Back PCB Schematic Diagram PCB Circuit Diagram ASSY-PCB Part List Part Code Code no Qty Description Spercificatio RemarkSetting up a wash machine Remove the safety device for carriageInstall the wash machine on the leveled place Initial assembled condition assy cover topCondition of setting up sink Disassembled Assy- Cover Top Door Opening DimensionSlim Model SideAssemble and Disassemble ASSí Y-COVER TOPBelt Tools for Disassembly and Assembly ToolTopfront Exploded View TUB Exploded View Case Exploded View Parts List SEAL-OILTS0-PJT,NBRSD35,BLK,-,-,-,JIN Screw/Bolt List Electronics