7. General Error Function
-If the same signal as the above table is detected for more than 5 seconds, it is a PRESSURE S/W Error.
-When the error occurs, water drain pump will operate for 3 min. and then turn off the water drain pump.
Then the display shows fig. 8 indicating a pressure s/w error indicator.
8. ABNORMAL WATER TEMPERATURE ERROR
-In case the water temperature is 50∞C or more in Delicate and Wool course.
-At the time of initial water supply, if the water temperature is not appropriate, water starts to be drained and it is forced to be drained for 2 min when the abnormal frequency of 24.5KHz is detected.
-Display shows fig. 9
-This error can be cleared by POWER S/W OFF.
9. WATER LEAKAGE ERROR (E9)
-Water Leakage error occures when water is drained naturally after washing program starts.
10. Tacho Error
-This error occurs in case motor thaco is out of order or tacho siganals inputted are fewer than 2
-Display shows fig. 11
-This error can be cleared by power s/w off
11. Motor Triac short Error
-This error occurs in case over 300 per 1 sec tacho signals are inputted power S/w should be off.
-fig. 12 is diplayed.
- This error can be cleared by power s/w off
12. Thermistor error
-This error occurs, when Thermistor circuit is abnormal or the detected electrical volt is 0.2v below or 4.5v over
-fig. 13 is displayed
-This error can be cleared by power s/w off
fig. 8
fig. 9
fig. 10
fig. 11
fig. 12
fig. 13