7. General Error Function
When an error occurs, this function starts to keep generating error melody sounds and displays error indicators as shown in the followings per corresponding error by blinking in 0.5sec interval until the error status is completely cleared out. In this case, all the driving devices are turned off until the error is cleared out.
|
| ○ : Light on |
|
1. WATER SUPPLY ERROR |
| ● : Light off |
|
- Display shows such as fig. 1 |
|
|
|
- Water Supply Error occurs when water level frequency does not show |
|
|
|
changes more than 100Hz or water is not supplied |
|
|
|
up to the water level presetting for 20 min or more at the time of initial |
|
|
|
water supply. |
|
|
|
|
|
| |
resuming the POWER ON initial status. | fig. 1 |
| |
|
|
2. WATER DRAIN ERROR
- Display shows such as fig.2
- In case the water level frequency is 24.5KHz or less in the initial phase of
- Water Drain error can be cleared by turning POWER S/W OFF and resuming the POWER ON initial status.
fig. 2
3. OVER-FLOW ERROR
- Display shows such as fig.3
-
Water is drained prior to POWER S/W OFF and it is forced to be drained for 2 min if a frequency of more than 24.5 KHz is detected.
| fig. 3 |
4. UNBALANCE ERROR |
|
| |
- Display shows such as fig4. |
|
- Laundry load is unbalanced; loosen any tangled laundry. |
|
- If only one item of clothing needs washing, such as a bathrobe or jeans, |
|
the final spin result might be unsatisfactory and an error message will be |
|
shown in the display panel such as fig 4.. |
|
| |
- Unbalance error is cleared by POWER S/W OFF and by resuming the | fig. 4 |
POWER ON initial status. |
|
5. WATER HEATER ERROR |
|
- Display shows such as fig.5 or fig.6 |
|
- In case the water temperature rises by 7∞C or more in 1 min. or by 2∞C |
|
less in 10 min after heating is started. |
|
- It can be cleared by turning POWER S/W OFF. | fig. 5 |
| |
| fig. 6 |
6 DOOR OPEN ERROR
- Display shows such as fig.7
- Door Open error can be cleared by closing the door.
fig. 7
7. ASSí Y PRESSURE S/W ERROR
* Generated Frequency Signal of WATER LEVEL(W/L) S/W (KHz)
| Level | Low Level | High Level |
|
| Abnormal W/L Frequency | 30.00 KHz | 15.00 KHz |
|
|
|
|
|
|
12