Problem | Possible Cause | Repair Procedure | |
|
| 1g. Set to start of regular wash cycle. Test for | |
|
| 115 vac between high side of hot and cold water | |
| 1g. Timer | inlet valves and common (low) side of water | |
|
| inlet valves. If not present, the timer may be | |
|
| defective. | |
|
| 1h. Set to Start of the regular wash cycle. Set | |
|
| water temperature selector to WARM/COLD. | |
| 1h. Temperature Selector Switch | Test for 115 vac between high side of hot and | |
|
| cold water inlet valves and common (low) side | |
|
| of water inlet valves. If not present the selector | |
|
| switch may be defective . | |
|
| 1i. If 115 vac is present across a water inlet | |
| 1i. Water inlet valves. | valve coil and water pressure is present, the | |
| machine should fill. If not, the valve may be | ||
|
| ||
|
| defective. | |
2. Fills, won't | 2a. Belt. | 2a. Check belt, adjust tension. | |
agitate | |||
|
| ||
|
|
| |
|
| 2b. Test signals at the Control Module. See | |
|
| Testing the Electronic Control Module. If correct, | |
| 2b. Electronic Control Module | replace the Control. If test on terminals 1 to 7 | |
|
| fail, replace timer. If tests on terminal 8, 9, 12 | |
|
| through 15 fail, replace motor. | |
|
|
| |
| 2c. Motor | 2c. Check motor resistance. See Testing Drive | |
| motor. | ||
|
| ||
3. Won't drain | 3a. Filter | 3a. Remove, clean, and replace filter. | |
| 3b. Drain hose | 3b. Check for kinks or blockage. | |
|
|
| |
| 3c. Drain | 3c. Drain standpipe inlet more than 36" above | |
| the floor. Blocked drain. (direct connection) | ||
|
| ||
|
| 3d. With power off, run pump cooling impeller | |
| 3d. Pump | manually to check for jamming. If pump does | |
| not turn freely, disassemble, remove foreign | ||
|
| ||
|
| objects, and reassemble. | |
|
|
| |
|
| 3e. Set timer to REGULAR SPIN. Test for 115 | |
| 3e. Timer | vac across the pump terminals. If present, the | |
| pump may be defective. If not present, timer | ||
|
| ||
|
| may be defective. | |
4. Won't spin. | 4a. Belt. | 4a. Check belt, adjust tension. | |
|
|
| |
| 4b. Electronic Control Module | 4b. Test Control Module in accordance with the | |
| appropriate procedure. | ||
|
| ||
| 4c. Overloaded | 4c. Reduce load size. | |
| 4d. Wet load | 4d. Check water inlet valves for leaks. See #3 | |
|
|
|
3