4)HSI (Hot Surface Ignition) 24 VAC Transformer

The HSI transformer is designed to step down the operating voltage of the dryer to 24 VAC to operate the HSI module. This transformer, like all transformers, is two (2) sided:

a)Primary Side

This is the incoming voltage side - 120 VAC, 208 VAC, 240 VAC - of transformer.

b)Secondary Side

This is the step down side - 24 VAC - of the transformer.

WARNING: 208 VAC and 230/240 VAC ARE NOT THE SAME. ALL voltage connections should be checked and confirmed according to the wiring diagram provided with the individual dryer. Any damage done to dryer components due to improper voltage connections will automatically

VOID THE WARRANTY.

IMPORTANT: The ADC Service Department must be contacted prior to any wiring change and/or conversion because, depending on the change/ conversion required, some parts may have to be added, deleted, or changed. When contacting the ADC Service Department they must be given the correct model number and serial number of the dryer(s).

NOTE: Any wiring change(s) and/or conversion(s) should be by a QUALIFIED ELECTRICAL TECHNICIAN.

(1) Transformer Wiring

There are six (6) color-coded wires coming from the 24 VAC Transformer. There are four (4) wires coming from the primary (incoming) voltage side of the trans- former. Their application and color-coding are as follows:

(a) For 120 VAC application ONLY;

1 - The BLACK and WHITEwires are used. 2 - The Red and Blue wires are capped off

individually.

(b) For 208 VAC application ONLY;

1 - The BLACK and BLUE wires are used. 2 - The Red and White wires are capped off

individually.

(c) For 240 VAC application ONLY;

1 - The BLACK and RED wires are used.

2 - TheWhite andBlue wires are capped off individually.

There are two (2) ORANGE wires coming from the secondary (step down) side of the transformer;

(d)One (1) ORANGE wire is connected to the GND (ground) termination.

(e)One (1) ORANGE wire supplies the 24 VAC signal for the control and/or HSI system circuit. (Refer to the specific wiring diagram with the dryer for connection point.)

12

Image 14
Contents Fall River MA American Dryer CorporationCurrant Road Retain This Manual In a Safe Place For Future Reference Table of Contents Introduction HOT Surface Ignition HSI System COMPONENTS/FUNCTIONSVAC Transformer 36E Redundant Gas Valve System basic Electrical RATINGS/SPECIFICATIONS HSI System OperationHSI System Operation Flow Chart Computer Calls For HeatTroubleshooting Normal Operation summaryHSI Hot Surface Ignition Troubleshooting Terms definitions Test Equipment TROUBLESHOOTING/SYSTEM Diagnosis detailed Never Test for Leaks with a FlameInches W.C Terminal Designations Void the Warranty Replacement Coils are not Available 128974 128918128927 881479HSI Hot Surface Ignition System Components ADC 450401 1-05/20/97-50 2-02/25/98-50