(1)Recovery from LOCKOUT requires a manual reset by either resetting the thermostat or removing the 24 VAC from the HSI module for a period of five
(5)seconds.
(2)If the microprocessor (computer) is still calling for heat after one (1) hour, the HSI module will automatically reset and attempt to ignite the burner again.
2)Flame Failure Reignition
a)If the established flame signal is lost while the burner is operating, the HSI module will respond within 0.8 seconds. The gas valve is
IMPORTANT: The HSI MODULE is a precision instrument, and should be handled carefully. ROUGH HANDLING or DISTORTING COMPONENTS COULD CAUSE THE MODULE TO MALFUNCTION.
WARNING: THE HSI MODULE IS NOT FIELD REPAIRABLE.
NOTE: To reset the HSI MODULE if it is in the LOCKOUT MODE, open and close the main door then restart the dryer. If the module repeatedly goes into LOCKOUT, refer to the TROUBLESHOOTING SECTION of this manual.
b)The 24 VAC TRANSFORMER is designed to step down the operating (primary) voltage of the dryer from 120 VAC, 208 VAC, or 240 VAC to the 24 VAC (secondary voltage) which is necessary to operate the HSI system and in some cases the controls of the dryer.
The 24 VAC TRANSFORMER has
24 VAC Transformer