American Dryer Corp ADG-530 technical manual 36E Redundant Gas Valve

Page 6

c. The HOT SURFACE IGNITOR/FLAME SENSOR ASSEMBLY is located in the burner flame area and is used to ignite the gas by the use of a HOT SURFACE IGNITOR. To provide feedback information to the HSI module a FLAME SENSOR is used to determine whether the burner flame is evident (on).

The HOT SURFACE IGNITOR is a silicon carbide ignitor that upon application of 24 VAC will glow bright orange for the inter-purge time period. The proper location of the silicon carbide ignitor is very important to achieve optium system performance for both ignition and flame sensing.

After the inter-purge period the gas valve will open.

Upon ignition, the resistance in the flame sensor electrode changes and the in- formation is sent to the HSI module via the sensor probe lead connection to the module. Once the resistance is changed and sensed, the HSI module will sustain the gas flow (provide 24 VAC power to the gas valve).

Upshot Burner Tube

with Hot Surface Ignitor (HSI)/Flame Sensor Assembly

d. The HSI 24 VAC GAS VALVE(s) used are of the redundant type which means the gas valve is actually two gas valves in one; one in series with the other. This is a safety feature which provides protection against gas flow in the event of a failure of one of the valves to seat properly. Other features are that the gas valves have a manual shut off, a pressure tap outlet, and are designed for easy conversion to regulated L.P. gas.

36E Redundant Gas Valve

WARNING: THE HSI GAS VALVES ARE NOT FIELD REPAIRABLE.

IMPORTANT: THERE ARE NO PARTS AVAILABLE FOR FIELD REPAIR. Replace gas valve only with exact model and/or type number as noted on gas valve.

4

Image 6
Contents American Dryer Corporation Currant RoadFall River MA Retain This Manual In a Safe Place For Future Reference Table of Contents Introduction HOT Surface Ignition HSI System COMPONENTS/FUNCTIONSVAC Transformer 36E Redundant Gas Valve System basic Electrical RATINGS/SPECIFICATIONS HSI System OperationHSI System Operation Flow Chart Computer Calls For HeatTroubleshooting Normal Operation summaryHSI Hot Surface Ignition Troubleshooting Terms definitions Test EquipmentTROUBLESHOOTING/SYSTEM Diagnosis detailed Never Test for Leaks with a FlameInches W.C Terminal Designations Void the Warranty Replacement Coils are not Available 128974 128918128927 881479HSI Hot Surface Ignition System Components ADC 450401 1-05/20/97-50 2-02/25/98-50