Whirlpool W10222384A important safety instructions VentingRequirements, Vent material

Page 6

Must include a shutoff valve:

An individual shutoff valve must be installed within

six (6) feet (1.8 m) of the washer/dryer in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54. The location should be easy to reach for opening and closing.

A

B

C

D

A. Gas shutoff valve

B. 18" NPT minimum plugged tapping C. ½" NPT gas supply line

D. Gas supply line coupling 34" (864 mm) min. to 37" (940 mm) max. from floor

Burner input requirements:

Elevations up to 10,000 ft (3,048 m):

The design of this washer/dryer is certified by CSA International for use at altitudes up to 10,000 ft (3,048 m) above sea level at the Btu rating indicated on the model/serial number plate. Burner input adjustments are not required when the dryer is operated up to this elevation.

Elevations above 10,000 ft (3,048 m):

When installed above 10,000 ft (3,048 m), a 4% reduction of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft (305 m) increase in elevation.

Gas supply pressure testing

The washer/dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than ½ psi.

Dryer gas connection

This washer/dryer is equipped with its own permanent, flexible gas connector, design-certified by CSA International, for connecting the washer/dryer to the gas supply line.

Flexible gas connector

VentingRequirements

WARNING

Fire Hazard

Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

WARNING: To reduce the risk of fire, this washer/dryer

MUST BE EXHAUSTED OUTDOORS.

IMPORTANT: Observe all governing codes and ordinances.

The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building.

If using an existing vent system

Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint.

Replace any plastic or metal foil vent with rigid or flexible heavy metal vent.

Review Vent system chart. Modify existing vent system if necessary to achieve the best drying performance. Only rigid or flexible metal vent shall be used for exhausting.

If this is a new vent system

Vent material

Use a heavy metal vent. Do not use plastic or metal foil vent.

4" (102 mm) heavy metal exhaust vent and clamps must be used. DURASAFE™ venting products are recommended.

4"

102 mm

4" (102 mm) heavy metal exhaust vent

DURASAFE™ vent products can be purchased from your dealer or by calling Whirlpool Parts and Accessories. For more information, see the “Assistance or Service” section of the Washer/Dryer User Instructions.

Rigid metal vent

For best drying performance, rigid metal vents are recommended.

Rigid metal vent is recommended to avoid crushing and kinking.

Flexible metal vent

Flexible metal vents are acceptable only if accessible for cleaning.

Flexible metal vent must be fully extended and supported when the dryer is in its final location.

6

Image 6
Contents WASHER/DRYER Safety Tools needed ToolsandPartsParts needed for washer not provided Inlet hosesAlternateParts LocationRequirementsDrainSystem Electrical Requirements Gas Type Natural GasGas supply line VentingRequirements Vent materialInstall the front leveling legs Install Leveling LegsInstall the rear leveling legs For mobile home useRemoveFoamPacking ConnectDrainHoseConnectInletHoses SecureDrainHose PlanVentSystemSpecial provisions for mobile home installations Optional exhaust installationsAlternate installations for close clearances Determine vent pathLevelWasher/Dryer InstallVentSystemVent system chart MakeGasConnectionIf the dryer will not start, check the following Complete InstallationCheck that you have all of your tools W10222384A