Kenmore 8789, 110.8787 Electrical Requirements, It is your responsibility, Electrical Connection

Page 8

Electrical Requirements

It is your responsibility

To contact a qualified electrical installer.

To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances.

The National Electric Code requires a 4-wire supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.

A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.

To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

Do not use an extension cord.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Electrical Connection

To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

If local codes do not permit the connection of a neutral ground wire to the neutral wire, see “Optional 3-wire connection” section.

This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground wire is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground wire must be removed from the external ground conductor screw (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground wire is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.

A 4-wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations,

(2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors.

If using a power supply cord:

Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:

A UL listed 30-amp power supply cord, rated

120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.

A UL listed strain relief.

If your outlet looks like this:

4-wire receptacle (14-30R)

Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.

If your outlet looks like this:

3-wire receptacle (10-30R)

Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 10-30R.

If connecting by direct wire:

Power supply cable must match power supply (4-wire or 3-wire) and be:

Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), protected with flexible metallic conduit. All current-carrying wires must be insulated.

10-gauge solid copper wire (do not use aluminum).

At least 5 ft (1.52 m) long.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

For a permanently connected dryer:

This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer.

WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

SAVE THESE INSTRUCTIONS

8

Image 8
Contents Electric Dryer Table of Contents Protection AgreementsKenmore Elite Appliance Warranty ONE Year Limited WarrantyDryer Safety Your safety and the safety of others are very importantOptional Pedestal Installation InstructionsTools and Parts Installation clearances Dryer DimensionsCustom undercounter installation Dryer only Location RequirementsInstallation spacing for cabinet installation Mobile home additional installation requirementsCloset installation Dryer only Mobile home installations requireElectrical Connection Electrical RequirementsIt is your responsibility Electrical Connection Power Supply Cord Direct WireStyle 1 Power supply cord strain relief Wire connection Power supply cord Style 2 Direct wire strain reliefWire connection Direct wire Remove center silver-colored terminal block screwBDE CG F Optional 3-wire connection If this is a new vent system Vent material If using an existing vent systemVenting Requirements Plan Vent System Optional exhaust installationsAlternate installations for close clearances Install Vent System Install Leveling LegsSpecial provisions for mobile home installations Vent system chartConnect Vent Level DryerReverse Door Swing Remove the doorComplete Installation Reinstalling the doorReverse the door handle If the dryer will not start, check the followingDryer USE Starting Your DryerTo use an Auto Cycle To make changes during an Auto CyclePausing or Restarting Stopping Your DryerControl Locked Drying and Cycle TipsStatus Lights CyclesOptions Modifiers Changing Cycles, Options and ModifiersTumble Free Heated Dryer Rack End of Cycle SignalEnd of Cycle Signal Dryer Care Dryer Operation TroubleshootingChanging the Drum Light Dryer Results Índice Contratos DE ProtecciónContratos Maestros de Protección Servicio de Instalación de SearsGarantía DE LOS Electrodomésticos Kenmore Elite Garantía Limitada DE UN AÑOSeguridad DE LA Secadora Su seguridad y la seguridad de los demás es muy importanteInstrucciones DE Instalación Herramientas y piezasPedestal opcional Requisitos de ubicaciónInstalación en el clóset Sólo secadora Dimensiones de la secadoraEspacios para la instalación Requisitos eléctricos Espacio para la instalación en un armarioUsted es responsable de Las instalaciones en casas rodantes necesitanConexión eléctrica Si emplea un cable de suministro eléctricoSi el contacto de pared luce como éste Si hace la conexión con cableado directoCable directo Conexión eléctricaCable de suministro eléctrico Conexión de 4 hilos Cable de suministro eléctrico Estilo 2 Protector de cables para cable directoConexión de 4 hilos Cable directo Tornillo conductor de tierra externoConexión de 3 hilos Cable de suministro eléctrico Conexión de 3 hilos Cable directoConexión opcional de 3 hilos Si éste es un nuevo sistema de ventilación Requisitos de ventilaciónSi usa un sistema de ventilación existente Instalaciones opcionales de escape Instalaciones alternas para espacios limitadosCuadro del sistema de ventilación Instalación del sistema de ventilaciónDeterminación de la vía del ducto de escape Instalación de las patas niveladoras Conexión del ducto de escapeNivelación de la secadora Inversión del cierre de la puertaInversión de la bisagra Inversión de la manija de la puertaSi la secadora no funciona, revise lo siguiente Complete la instalaciónReinstalación de la puerta Para usar un ciclo de secado automático USO DE LA SecadoraPuesta en marcha de la secadora Detención de la marcha De la secadora Pausa o reanudación de la marchaControl bloqueado Sugerencias de ciclos y secadoLuces de estado CiclosPantalones de mezclilla Jeans Secado expreso Express DRYInformal Casual Ropa delicada DelicateOpciones ModificadoresEstante térmico de la secadora Cambio de ciclos, opciones y ModificadoresSeñal de fin de ciclo Cuidado DE LA Secadora Limpieza del filtro de pelusaLimpieza de cada carga Limpieza según la necesidadCambio de la luz del tambor Limpieza del interior de la secadoraEliminación de pelusa acumulada Resultados de la secadora Solución DE ProblemasFuncionamiento de la secadora El tiempo del ciclo es demasiado corto Pelusa en la ropaManchas en la carga o en el tambor Ropa arrugadaW10114657

8789, 110.8787 specifications

The Kenmore 110.8787 and 110.8789 are prominent models in the Kenmore washing machine lineup, designed to provide efficiency, durability, and advanced cleaning performance. These machines are known for their stylish design and user-friendly features that cater to various laundry needs.

One of the standout characteristics of the Kenmore 110.8787 and 110.8789 is their capacity. With a sizable drum, these washers can accommodate larger loads, making them ideal for families or individuals who frequently wash bulky items like bedding and towels. This larger capacity not only saves time by allowing users to wash more items per load but also promotes better water and energy efficiency.

These machines feature a range of wash cycles designed to handle different fabric types and soil levels. With options such as normal, delicate, heavy-duty, and quick wash, users can customize their laundry experience based on their needs. The intuitive control panel simplifies the process, ensuring that selecting the appropriate cycle is straightforward.

Another significant technological advancement in the Kenmore 110.8787 and 110.8789 is their advanced agitation system. These washers utilize a combination of traditional agitator motion and modern washing technologies, which provide optimal cleaning performance while being gentle on clothes. The machines also incorporate smart sensors that adjust water levels and wash times according to the load size, ensuring resource efficiency.

Energy efficiency is a key selling point for both models, which are designed to consume less water and electricity compared to older washing machines. With ENERGY STAR certifications, users can expect lower utility bills without compromising on performance. The durable construction of the Kenmore 110.8787 and 110.8789 also means that these machines are built to last, featuring high-quality components that withstand regular use.

In addition to performance and efficiency, convenience features such as delay start, end-of-cycle signal, and lint filters make these washers very user-friendly. The sleek design fits well in any laundry room environment, enhancing aesthetics while providing top-notch functionality.

In summary, the Kenmore 110.8787 and 110.8789 washing machines stand out for their impressive capacity, multiple wash cycles, energy efficiency, and thoughtful design. Whether tackling everyday laundry or dealing with particular items, these machines offer a reliable and effective solution for all household washing needs.