Kenmore 8907 manual Metallic, Flexible, METHOD1

Page 11

II

Vent system chart

NOTE: Side and bottom exhaust installations have a 90 ° turn

inside the dryer. To determine maximum exhaust length, add one 90 ° turn to the chart.

Weather Hood Type

Recommended , Use oNy for short-run installation

 

4"

(10.16 cm)

2.5"

(6.35 cm)

No. ofg0 °

Rigid

Metallic

Rigid

Metallic

elbows

 

Flexible*

 

Flexible*

024.4 m(80 ft.) 12.4 m(41 ft.) 22.6 m(74 ft.) 10.1 m (33 ft.)

120.7 m(68 ft.) 11.2 m(37 ft.) 18.9 m(62 ft.) 8.8 m(29 ft.)

217.4 m(57 ft.) 10.1 m(33 ft.) 15.5 m(51 ft.) 7.6 m(25 ft.)

314.3m (47 ft.) 9.0 m (29 ft.) 12.5m(41 ft.) 6.5m(21 ft.)

*Do not use non-metallic flexible duct.

1, Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood.

2.Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.

,3. Run vent to dryer location. Use the straightest path possible. See "Determine vent path" in "Plan Vent System." Avoid 90 ° turns. Use clamps to seal all joints. Do not use duct tape,

screws or other fastening devices that extend into the interior of the vent to secure vent.

METHOD1

The dryer must be connected to the cold water faucet using the new inlet hoses. Do not use old hoses.

1.if space permits, attach the brass female end of the "Y" connector to the cold water faucet.

2.Turn the cold water faucet off.

3.Attach the straight end of long hose to "Y'connector.

4.Using pliers, tighten the coupling with an additional two- thirds turn.

_Do

not overtighten, as it may damage the coupling.

5.Attach angled end of long hoses to fill the valve at the

bottom of the dryer's rear frame. Screw on coupling by hand until it is seated on fill valve connector.

6.Using pliers, tighten the coupling with an additional two- thirds turn.

[_Do

not overtighten, as it may damage the coupling.

7.Check that the water faucets are on.

8.Check for leaks around "Y" connector faucets and hoses.

/'

/

//

1, Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in dryer, if connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood. Check that the vent is secured to exhaust hood with a 4" (10.2 cm) clamp.

2, Move dryer into its final location. Do not crush or kink vent.

3.(On gas models) Check that there are no kinks in the flexible gas line.

4, Once the exhaust vent connection is made, remove the corner posts and cardboard.

11

[BETTER]592-89075-02865

A-02EN.indd

11

2011-03-23

/,_f19:49:17

I

 

 

 

Image 11
Contents Electric Dryer Table of Contents Protection Agreements Pedestal Product Record Kenmore Appliance WarrantyProduct Record Including Dryer SafetyYour safety and the safety of others are very important IMPORTANT Safety iNSTRUCTiONSHose Water PedestalMANUAL=BOOK You willneed Dryer DimensionsCustom undercounter installation Dryer only Explosion HazardIVlobile home installations require Mobile home =additional installation requirementsCloset installation Dryer only Installaon spacing for cabinet installationIt is your responsibility Electrical Shock HazardFlexible metal vent Fire HazardElbows ClampsDetermine vent path Special provisions for mobile home installationsOptional exhaust installations LOCATIONCONSiDERATiONSMETHOD1 MetallicFlexible Method2 Iii!!,Cilii!!!O¸¸S,OSwiii!i!!¸ iiiiii,!!!!iiiiilI BETTER592-89075-02865 02EN.indd 2011-03-23 94920 Fire Hazard Dryer USEModels Models Air FluffDigital GraphicDisplay Dryness Level Salecon ButtonMixed Load Bell Wrinklerq Pr6venti0nduTemp Selection Button Suggested Items Suggested Temp Settings Installingthe drying rackHow to Set Setting/ReleasingLoad the dryer properly Cleanthe lintfilterDryer Care Explosion HazardPlastica shower curtains, outdoor furniture covers, etc Fromthe ExhaustVentTime WrinkleCycle Cooling Guard= Eeprom TroubleshootingLong, or lead istoo hot Loadsare wrinkled I94927 Iiiiiiiiiiiiiii =800=4= IiiiiiiiiiiiiiiilIiiiiiiiiiiiiiiiii Iiiiiiiiiiiiiii